2. Technical Data Diamond digital
20
2.1.4 INTERFACE DATA
– 8 tally inputs 2 D-sub socket 9-pin
TTL internal pull-up,
control with dry contact
– 12 + 5 tally outputs 2 D-sub connector 50-pin
1 potential-free contact 24 V, 1 A for
sources (12)
contact 24 V, 1 A with common root for
monitor (5),
– 8 GPI inputs, 8 GPI outputs D-sub socket 25-pin
inputs: TTL with optocoupler,
control with dry contact,
outputs: potential-free contact 24 V, 1 A
– 3 serial ports (E-box) D-sub socket 9-pin, RS 422,
1 serial port (E-box) D-sub socket 9-pin, RS 422 or RS 232,
switchable
– Service port (E-box) D-sub socket 9-pin, RS 232C
– Remote (E-box) 1 BNC (remote), cheapernet,
50 ohms, 150 m,
with repeater max. 2.5 km,
can be looped through with a T-junction
– Remote (control panel) 1 BNC (remote), cheapernet,
50 ohms, 150 m,
with repeater max. 2.5 km,
can be looped through with a T-junction
– 1 serial port (control panel) D-sub socket 9-pin, RS 422,
1 mouse port (control panel) D-sub connector 9-pin, RS 232C
– Service port (control panel) D-sub socket 9-pin, RS 232C,
optionally mouse or service,
switchable
2.1.5 POWER SUPPLY
– Line voltage AC 115 or 230 V +15/– 20 %,
switchable
– Line frequency 50/60 Hz ± 5 %
– Current consumption E-box 115V: 3.9 A, 230V: 2 A
– Current consumption panel 115V: 0.5 A, 230V: 0.25 A
– Cut-in current < 16 A, < 100 A transient
– Fuses Panel: 2 x 6,3 A slow-blow (IEC127 type)
Ebox: 2 x 10 A slow-blow (IEC127 type)
Manufacurer: Wickmann, Schurter
– Power connection Appliance inputs IEC 320 type,
VDE 0625 Part 1
– Safety regulations VDE 0805/5.90 (EN 60950)
– Power cords HAR cord H05VV–F1,0 2.5m
– US power cords Panel: SJT 2.5m 3x AWG18
EBox: SJT 3m 3x AWG18