1. GeneralDiamond digital
11
1.4.3 VIDEO OUTPUTS
The switcher is provided with the following video outputs:
• 4 program outputs
• 1 clean-feed output (before or between DSK, switchable)
• 1 output for second DSK preview in PP stage
• 3 program outputs for each mixing level
For preview purposes, the following outputs are available:
• 1 preview output for each mixing level, mask signal and wipe pattern signal
can be additively connected with the video signal.
• 1 preset output for preset/program stage, mask signal and wipe pattern sig-
nal can be additively connected with the video signal.
All outputs are delay-compensated. The digital horizontal and vertical blanking in-
tervals are transparent for the background signal. For the case of routing switcher
changeovers in the vertical blanking interval, the lines 6 and 319 are faded to black.
1.4.4 FURTHER OUTPUTS
For special applications (integration of a DVE, preview of sources, measuring pur-
poses), the switcher is provided (standard feature) with 5 (DD10) or 5 to 11
(optional for DD20 and 30) serial AUX outputs which can be optionally connected
with the following signals:
• all inputs
• all central mattes
• PGM: ME 1-2, PP, DSK (depending on the expansion phase)
• PVW: ME 1-2, PP, DSK (depending on the expansion phase)
• the signals of the frame stores (4:2:2)
• DVE output; for background/fill per ME, selectable
• DVE output for key per ME, selectable
Selection is made on the control panel or the external AUX control units.
1.4.5 REMOTES
The following interfaces are provided:
• 3 serial interfaces RS 422 for edit, DVE, external routing switchers.
• 1 serial interface; RS 423 (ES-BUS) or RS 422, switchable.
• 8 universal interface inputs (general-purpose interface, GPI) and 8 GPI out-
puts.
• For red tally, one potenial-free contact is provided per source. Furthermore,
the individual mixing levels are indicated.
• Tally input