5.8.3 ADJUSTING THE DISPLAY ADDRESS
Communication between the computer in the control panel and the status dis-
play takes place in one direction only.
The computer in the control panel transmits data to the status display, contai-
ning beside a sync character and the 4 ASCII characters (source name) also
an individual address. It is possible to select two monitor ident protocols:
Mon.-Ident/I: In this protocol, the displays for the switcher sources are di-
rectly assigned to the inputs, i.e. input 1 is always shown in dis-
play 1, input 2 in display 2 etc.
Mon.-Ident/B: In this protocol, the displays for the switcher sources are as-
signed to the keys on the routing switcher, i.e. the contents of
the display depends on the assign table.
The address consists of a hex character and has to be adjusted on each indivi-
dual status display according to the following table:
Monitor addresses:
Monitor Hex addresses