Installation manual
7. Description of the Interface Diamond digital
112
Each master control panel RPD-xx allows connection of up to four AUX panels to
the serial port (RS-422). Previously, the address has to be adjusted at each AUX
panel, adjusting at each of the four AUX panels another address.
Proceed as follows:
1. Remove on the rear of the panel the small cover cap, revealing a DIP switch
module with 8 switches.
2. Adjust the DIP switches 1 to 8 as follows:
(0 means switch OFF = downwards, 1 means switch ON = upwards)
Schalter 12345678
1. Panel 00000001
2. Panel 10000001 Is applicable up to
3. Panel 01000001 software DS0011F
4. Panel 11000001
From software version ”DS0011G” which replaces the under–monitor dis-
plays, the switches have to be set as follows:
Schalter 12345678
1. Panel 00001111
2. Panel 10001111
3. Panel 01001111
4. Panel 11001111
3. Fasten the cover cap.
4. Connect the panels among each other and with the serial port of the master
control panel. For this purpose, a 9-wire cable with 9-pin Sub-D connectors is
required (connected) by means of which the sockets MPK of the AUX panels
and the serial port of the master control panel are connected.
AUX-CP
MPK
AUX-CP
MPK
AUX-CP
MPK
AUX-CP
MPK
RPD 10
5. Apply 5V DC to the AUX panels.
6. Select the protocol AUX / UMD in the SETUP of the master control panel at
PORTP.
Installation