User’s Manual Stand Type Windows-based Terminal Contact your system administrator for details such as settings of the unit.
English SAFETY SYMBOLS This manual uses the safety symbols below. They denote critical information. Please read them carefully. WARNING Failure to abide by the information in a WARNING may result in serious injury and can be life threatening. CAUTION Failure to abide by the information in a CAUTION may result in moderate injury and/or property or product damage. Indicates a prohibited action. Indicates to ground for safety. Copyright© 2004 EIZO NANAO CORPORATION All rights reserved.
English Table of Contents PRECAUTIONS ...................................................................................... 4 1. INTRODUCTION ..................................................................................... 8 1-1. General Description ......................................................................................8 1-2. Features ........................................................................................................8 1-3. Package Contents..........................
English PRECAUTIONS IMPORTANT! • This product has been adjusted specifically for use in the region to which it was originally shipped. If operated outside the region to which it was originally shipped, the product may not perform as stated in the specifications. • To ensure personal safety and proper maintenance, please read this section and the caution statements on the unit (refer to the figure below).
English WARNING Keep small objects or liquids away from the unit. Small objects accidentally falling through the ventilation slots into the cabinet or spillage into the cabinet may result in fire, electric shock, or equipment damage. If an object or liquid falls/spills into the cabinet, unplug the unit immediately. Have the unit checked by a qualified service engineer before using it again. Place the unit at the strong and stable place.
English WARNING Maximum load capacity of AC outlet is 2 A. Connecting unit with more than 2 A may result in fire, electric shock or other damage. Use the correct voltage. * The unit is designed for use with a specific voltage only. Connection to another voltage than specified in this User’s Manual may cause fire, electric shock, or equipment damage. * Do not overload your power circuit, as this may result in fire or electric shock. Handle the power cord with care.
English CAUTION Handle with care when carrying the unit. Disconnect the power cord and signal cables and remove the optional unit. Moving the unit with the cord or the option attached is dangerous. It may result in injury. Do not block the ventilation slots on the cabinet. * Do not place any objects on the ventilation slots. * Do not install the unit in a closed space. * Do not use the unit laid down or upside down.
English 1. INTRODUCTION Thank you very much for purchasing the EIZO eClient SC1/SX1. 1-1. General Description The SC1/SX1 is used as a thin client, which connects to the terminal service installed Windows Terminal Server (Hereafter defined WTS) as listed below and accesses applications or data provided from the WTS.
English • EIZO Monitor detachable stand type • Secondary power switch (wired) 1-3. Package Contents Please contact your local dealer for assistance if any of the listed items are missing or damaged. Please make sure that all the items listed are in the package. • SC1/SX1 • Mouse (FDM-LCS1) • Power Cord • Switch Box (1.
English 2. OPERATION This chapter shows how to start and end SC1/SX1 operation. 2-1.
English NOTE • When turning off/on the unit, leave the unit off for a few seconds before turning it on again. • Do your part to conserve energy, turn off the unit when your finished using it. Complete energy use can only be stopped by disconnecting the unit from the power supply. Power Supply Control Switch (POWER SYNC) When the monitor's power cord is connected to the AC output power supply of SC1/SX1, the monitor’s power supply can be linked with on/off of SC1/SX1.
English 2-2. How to control (SC1) Logging on or off the WTS (SC1) Logging on to the WTS 1. Turn on the SC1. 2. The “Terminal Connection Manager” dialog box will be displayed. Please follow the instruction depending on the network environment of the SC1. (Contact your system administrator for the connection environment.) (1) Connecting and logging on to the WTS through the local network: Go to step 3.
English 3. Click the [Connections] tab. Select the desired [Connection Name] and click [Connect] (or simply double click the connection name). 4. The SC1 connects to the WTS and the “Log On to Windows” dialog box is displayed. Enter your [User name] and [Password], and then click [OK] to log on to the WTS. After logging on, the SC1 allows you to use the Microsoft Windows applications running on the WTS. NOTE • If an automatic logon connection is selected, this menu will not appear automatically. 2.
English Logging off the WTS If your SC1 starts its operation with a desktop: 1. Log off the WTS. (1) Close all the applications. (2) Select [Start] on the taskbar. (3) Select [Shut Down...] and select [Logoff] of the [Shut Down Windows] dialog box. (4) Click [OK] on the Logoff Window. The session ends and logs off from the WTS automatically. The “Terminal Connection Manager” dialog box will be displayed. If it’s connected through a dial-up, click the active button on the right bottom of the screen.
English If your SC1 starts its operation with an application: 1. Log off the WTS. Close the applications to log off from the WTS. The “Terminal Connection Manager” dialog box will be displayed. If it’s connected through a dial-up, click the active button on the right bottom of the screen. Click the button to disconnect the dial-up connection. 2. Follow the step 2 of “If your SC1 starts its operation with a desktop” to shut down the SC1.
English Opening/Closing the Local Web Browser Opening the Local Web Browser 1. Turn on the SC1. 2. The “Terminal Connection Manager” dialog box will be displayed. Please follow the instruction depending on the network environment of the SC1. (Contact your system administrator for the connection environment.) (1) If the web server is on the same network (Intranet): Go to step 3.
English Closing the Local Web Browser (SC1) 1. Close the local web browser. Select [Close] on the [File] and close the local web browser. The “Terminal Connection Manager” dialog box will be displayed. If a dial-up connection is made, click the active button on the right bottom of the screen. Click the button to disconnect the dial-up connection. 2. Shut down the SC1. There are 3 ways to shut down the unit.
English 2-3. How to control (SX1) Logging on or off the WTS (SX1) Logging on to the WTS 1. Turn on the SX1. 2. The Desktop screen will be displayed. When using the RDP protocol, proceed to step 3, and when using the ICA protocol, proceed to step 4. 3. When using the RDP protocol In case the connection icon exists on the desktop (1) Double click the connection icon (The example below is “RDP1”.). 18 2.
English In case the connection name doesn’t exist on the desktop (1) Double click the [Remote Desktop Connection] icon to open the [Remote Desktop Connection] dialog box. Click [Start]-[Remote Desktop Connection] to open the [Remote Desktop Connection] dialog box. Click [Start]-[Program]-[Remote Desktop Connection] to open the [Remote Desktop Connection] dialog box. (2) The [Remote Desktop Connection] will be displayed. Enter the name of the computer and click [Connect]. Proceed to step 5. 4.
English (2) The [Citrix Program Neighborhood] will be displayed. Double click the connection icon (The example below is “ICA1”). 5. When the SX1 connects to the WTS, the “Log On to Windows” dialog box is displayed. Enter your [User name] and [Password], and then click [OK] to log on to the WTS. After logging on, the SX1 allows you to use the Microsoft Windows applications running on the WTS. NOTE • If an automatic logon connection is selected, this menu will not appear automatically. 20 2.
English Logging off the WTS If your SX1 starts its operation with a desktop: 1. Log off the WTS. (1) Close all the applications. (2) Select [Start] on the taskbar. (3) Select [Shut Down...] and select [Logoff] of the [Shut Down Windows] dialog box. (4) Click [OK] on the Logoff Window. The session ends and logs off from the WTS automatically. 2. Shut down the SX1. Click [Start] and select [Shut Down…] and select the [Shut Down] of the [Shut Down Windows] dialog box.
English Opening/Closing the Local Web Browser (SX1) Opening the Local Web Browser 1. Turn on the SX1. 2. The desktop screen will be displayed. 3. Double click the [Internet Explorer] icon to open the browser. Click [Start]-[Internet Explorer] to open the browser. Click [Start]-[Program]-[Internet Explorer] to open the browser. 4. The local web browser opens. It is possible to browse web pages on the internet. Closing the Local Web Browser 1. Close the local web browser.
English 3. SPECIFICATIONS CPU and Memory CPU Memory Display Color VIA Eden, 800 MHz SC1 SX1 RAM: 128 MB, ROM: 32 MB RAM: 256 MB, ROM: 256 MB 256 / 65536 / 16 M colors Supported Resolution SC1 SX1 1280 × 1024 (60 Hz) 1280 × 1024 (60 Hz) 1024 × 768 (60 Hz) 1024 × 768 (60 Hz) 800 × 600 (60 Hz) 800 × 600 (60 Hz) 640 × 480 (60 Hz) Complying Protocol Software Microsoft Remote Desktop (RDP) Citrix Independent Computing Architecture (ICA) SC1 SX1 Microsoft Windows CE .NET 4.
English Environmental Specifications Temperature Certifications and Standards TÜV/NRTL, c-TÜV, FCC class A, CB Humidity 100-120 VAC range Operating: 5 °C to 35 °C to (41 °F to 95 °F) Storage: -20 °C to 60 °C (-4 °F to 140 °F) 30 % to 80 % R.H. Non-condensing 200-240 CE, CB, TÜV Rheinland/GS VAC range *1 Monaural microphone connector doesn’t support SC1. Dimensions Unit: mm (inches) 166(6.5) 55( 27(1.06) 2.1 7 200(7.9) ) 63( 2 5(0 .48) .2) Po r SY NC OF 89(3.5) we F ON 295(11.
LIMITED WARRANTY EIZO NANAO CORPORATION (“EIZO”) and EIZO authorized distributors warrant, subject to and in accordance with the terms of this warranty, to the original purchaser who purchased the product from EIZO or EIZO authorized distributors that this product shall be free from defects in material and workmanship for a period of three (3) from the date of purchase.
For U.S.A, Canada, etc. (rated 100-120 Vac) Only This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.