2. How to Adjust the Monitor
4
Measure the paper white
When colormunki is connected to the computer, turn the rotary disk to monitor measurement
mode.
Hold the measurement device as below, with the sensor facing the paper.
Move it approximately 25 cm away from the paper and maintain it parallel to the paper.
The use of the photo stands is recommended so that the paper will not move.
Click [Measure] on the paper white measurement window.
After the measurement, click [OK]. The measured values are set as the target brightness and white
of the configuration window. Click [OK].
Next, proceed to p.28 "9. Initialize the measurement device" and the further procedures.
Note
• In the paper white measurement, not only white point but also brightness is measured and
reflected in the target value.
• The target value of brightness is set by 5cd/m
2
, based on the rounded-up measurement value.
ex.) measured brightness : 80.1 cd/m
2
-> 85 cd/m
2
• If the measurement value of brightness is under 25 cd/m
2
, the target value of brightness is
automatically set to minimum value.
Approx. 25cm
colormunki