User Manual

39
Chapter 4 SelfCalibration
7. Choose “Gamma”, and press .
Setting Function
1.6-2.7 Set the gamma value.
Adobe®RGB Set the gamma curve dened by Adobe®RGB.
sRGB Set the gamma curve dened by sRGB.
EBU Set the gamma curve dened by EBU.
REC709 Set the gamma curve dened by REC709.
REC1886 Set the gamma curve dened by REC1886.
SMPTE-C Set the gamma curve dened by SMPTE-C.
DCI Set the gamma curve dened by DCI.
L* Set the perceptually uniform gamma curve dened by CIE1976.
Note
The color gradation adjustment results are reected and automatically become “Fixed” when adjusted
with ColorNavigator 6.
Press
after completing the setting.
8. After completing all settings, press .
4-5. Executing SelfCalibration
SelfCalibration can be executed manually regardless of the schedule.
Procedure
1. Choose “SelfCalibration” from the Adjustment menu, and press
.
2. Choose “Execute” from “SelfCalibration”, and press
.
The built-in calibration sensor is activated, and SelfCalibration is executed.
Attention
To execute SelfCalibration, it is necessary to set the calibration details. For more information,
see 4-4. Setting the calibration targets” (page 38).
After selecting “Execute”, warming up (after the power to the monitor is switched on, leaving the monitor on
for a certain period of time until the display becomes stable) may be executed before the built-in calibration
sensor comes out.