7 Mounting and installation
7.1 Dimensions / fastening dimensions
DANGER
Danger due to incorrect installation of the device!
Explosion protection is impaired!
Carry out installation strictly according to the instructions and national
safety and accident prevention regulations to maintain the explosion
protection.
Select and install the electrical device so that explosion protection is not
affected due to external influences, i.e. pressure conditions, chemical,
mechanical, thermal and electric impact such as vibration, humidity and
corrosion (see IEC/EN 60079-14).
The device must only be installed by trained qualified personnel. For this
purpose, it is absolutely imperative to have the knowledge of the
relevant standards (e.g. IEC/EN 60079-14).
Dimensional Drawings (All Dimensions in mm) - Subject to Alterations
15007E00
15006E00
Portable lamp Charging unit
14807E00
Drilling hole pattern for wall mounting bracket
135
39
55
74
126
131
64
90
ø 4,50