Drawing : - TPC408 Issue :-3 Date : - 08/08/14 RM85 INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC408 Issue :-3 Date : - 08/08/14 RM85 PACKAGE CONTENTS Item Description Quantity 10560RG-US Dehumidifier 1 3086144 Quick release hose coupling 1 3944110 PVC Tube – 3/8” I/D 7.
Drawing : - TPC408 Issue :-3 Date : - 08/08/14 INTRODUCTION Designed for a wide range of applications, the RM85 is a rugged, industrial unit, which utilizes an energy-efficient compressor and a compact portable design to provide easy efficient drying.
Drawing : - TPC408 Issue :-3 Date : - 08/08/14 SPECIFICATIONS MODEL: 10560rg-us HEIGHT: 37.2” (945mm) WIDTH: 21.5” (545mm) DEPTH: 19.4” (492mm) WEIGHT: 99 lbs (45 Kg) AIRFLOW: 230 CFM (390 M3/hr) POWER SUPPLY: 110V/ 60Hz/ 1 ph FINISH: Rotational Moulded polyethylene OPERATING RANGE: 33°F – 95°F REFRIGERANT: R-407c (17.6 oz) "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC408 Issue :-3 Date : - 08/08/14 OPERATION The following procedures should be followed to test the RM85 for correct operation: 1. After unpacking, examine all external features to confirm damagefree shipment. Report all defects and damage at once. Connect the power cable to a grounded 15 Amp electrical outlet. 2. Check dehumidification process as follows: CAUTION: DO NOT REMOVE COVERS WHEN UNIT IS IN OPERATION A. B. C. D. E. Place unit on a level surface.
Drawing : - TPC408 Issue :-3 Date : - 08/08/14 ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTNENANCE ON ITEMS 1, 2, 3, 4 & 5 To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC408 Issue :-3 Date : - 08/08/14 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC408 Issue :-3 Date : - 08/08/14 TROUBLESHOOTING SYMPTOM CAUSE Unit inoperative 1. No power to unit Little or no airflow 1. Fan motor burnt out 2. Dirty refrigeration coils 3. Loose electrical wiring Little or no water extraction 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas Little or no defrost when required 1. Faulty timer 2. Faulty by-pass valve Unit vibrates excessively 1. Loose compressor 2. Damaged fan Water flooding inside the machine 1.
Drawing : - TPC408 Issue :-3 Date : - 08/08/14 RM85 SPARE PARTS LIST NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 13 14 16 17 18 19 20 21 DESCRIPTION Timer Condenser coil Evaporator coil Cable & Tube wrap Drain tray Filter Capillary Solenoid valve Filter dryer Compressor Defrost Relay Solenoid coil Hour meter Run capacitor On/Off switch Power Relay Pump purge switch Fan Fan inlet ring Wheel Rubber foot Condensate pump Page 9 of 12 PART NUMBER 1619508 2029322 2029323 2056002 2056003 2056004 3014254 3020837 3
Drawing : - TPC408 Issue :-3 Date : - 08/08/14 Page 10 of 12
Drawing : - TPC408 Issue :-3 Date : - 08/08/14 Page 11 of 12
Drawing : - TPC408 Issue :-3 Date : - 08/08/14 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.