SYSTEM INSTALLATION
Positioning
Position the Timber Seasoner in the area leaving enough room at either end
of the unit to allow for servicing. Using a spirit level ensure the unit is level in
both directions. Failure to do so may result in the drain tray overflowing and
flooding the chamber
Wiring
Connect a suitable control system to the Terminal Block position at one end of
the equipment. See enclose wiring schedules in order to identify the correct
terminal position.
Drainage
Connect the outlet from the drain tray (located behind the front panel and
under the evaporator coils) to a permanent drain.
Ensure that the drainage does not rise above the level of the drain tray.
Failure to observe this requirement will result in internal flooding of the
dehumidifier.