SPECIFICATION
1330300
1330100
1330900
1330500
MF2 MF2S MF4 MF4S
Height 1,190 1,190 1,535 1,535 mm
Width 1,100 1,100 1,100 1,100 mm
Depth 460 460 460 460 mm
Weight 128 128 190 190 kg
Number Fans 1 1 2 2
Airflow 3,000 3,000 6,000 6,000 m3/hr
Supply Voltage 415 415 415 415 V
Supply Frequency 50 50 50 50 Hz
Power (Dryer) 3.0 3.0 6.0 6.0 kW
Power (Heating) 4.5 4.5 9.0 9.0 kW
Connected Load 8.0 8.0 16.0 16.0 kW
Refrigerant Type R22 R407c R407c R134a
Quantity 1.8K.g 2.7Kg 4.3K.g 5.0Kg
Max Drying Temperature 60 60 60 60 °C
Typical Extraction 60-150 60-150 120-300 120-300 l/24hr
Typical Wood Load 20 20 40 40 m3
Evaporator Coil Type Cu St/St Cu St/St
"This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The
refrigeration system is hermetically sealed.
The Global Warming Potential (GWP) of refrigerants used in products manufactured by Ebac
Industrial Products Ltd is as follows
R134a – 1300
R407c – 1610
For type and weight of refrigerant contained in this unit, please refer to the product data label"