Drawing : - TPC156 Issue :-1 Date : - 04/11/03 Technical Publication 1330300 1330100 1330900 1330500 - MF2 MF2S MF4 MF4S TIMBER SEASONER INSTALLATION, OPERATION & MAINTENANCE MANUAL www.eipl.co.
Drawing : - TPC156 Issue :-1 Date : - 04/11/03 CONTENTS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10.
Drawing : - TPC156 Issue :-1 Date : - 04/11/03 INTRODUCTION The purpose of the Ebac Timber Seasoner is to take the moisture out of the air of an enclosed space containing timber to be dried, thereby allowing the air to absorb more moisture from the timber and subsequently speeding up the whole drying process Fas inside the Timber Seasoner draws moisture laden air over the evaporator coil where it is cooled.
Drawing : - TPC156 Issue :-1 Date : - 04/11/03 SPECIFICATION 1330300 MF2 1330100 MF2S 1330900 MF4 1330500 MF4S Height Width Depth Weight 1,190 1,100 460 128 1,190 1,100 460 128 1,535 1,100 460 190 1,535 1,100 460 190 Number Fans Airflow Supply Voltage Supply Frequency Power (Dryer) Power (Heating) Connected Load Refrigerant Type Quantity 1 3,000 415 50 3.0 4.5 8.0 R22 1.8K.g 1 3,000 415 50 3.0 4.5 8.0 R407c 2.7Kg 2 6,000 415 50 6.0 9.0 16.0 R407c 4.3K.g 2 6,000 415 50 6.0 9.0 16.0 R134a 5.
Drawing : - TPC156 Issue :-1 Date : - 04/11/03 SYSTEM INSTALLATION Positioning Position the Timber Seasoner in the area leaving enough room at either end of the unit to allow for servicing. Using a spirit level ensure the unit is level in both directions. Failure to do so may result in the drain tray overflowing and flooding the chamber Wiring Connect a suitable control system to the Terminal Block position at one end of the equipment.
Drawing : - TPC156 Issue :-1 Date : - 04/11/03 OPERATION Although the operation tests will differ depending on which control system is being used, the basic points should be verified for correct operation Fan Operation Switch the unit on and ensure the airflow is discharged from the top of the unit.
Drawing : - TPC156 Issue :-1 Date : - 04/11/03 ROUTINE MAINTENANCE WARNING ISOLATE THE MACHINE AND CONTROL SYSTEM BEFORE CARRYING OUT ROUTINE MAINTENANCE To ensure continued full efficiency of the Timber Seasoner it should be subjected to periodic maintenance procedures as follows :• Clean the surface of the evaporator coil and condenser coils by blowing the dirt out from behind the fins with compressed air. Hold the nozzles of the air hose about 150mm away from the coil to avoid damaging the fins.
Drawing : - TPC156 Issue :-1 Date : - 04/11/03 REPAIRS Should an electrical component fail simply replace it with a spare supplied by the Manufacturers. If refrigerant gas is lost from the machine it will be necessary to use a Refrigeration Engineer to correct the fault. The type and quantity of refrigerant used can be found on the Serial Number plate normally positioned in the electrical box. It is essential that any refrigerant repairs are carried out by competent Refrigeration Engineers.
Drawing : - TPC156 Issue :-1 Date : - 04/11/03 TROUBLESHOOTING SYMPTON Unit Inoperative CAUSE 1. No Power to unit 1. 2. 3. 4. 5. Loose fan Fan motor burnt out Dirty refrigeration coils Loose electric wiring Fuse blown or circuit breaker tripped Little or no water extraction 1. 2. 3. 4. Insufficient air movement Compressor fault Loss of refrigerant gas Blocked filter dryer Unit vibrates excessively 1. Loose compressor 2. Damaged fan Water flooding 1. Drain pipe blocked or frozen 2.
Drawing : - TPC156 Issue :-1 Date : - 04/11/03 SPARES PARTS LIST Description Part No.
Drawing : - TPC156 Issue :-1 Date : - 04/11/03 Page 11 of 12
Drawing : - TPC156 Issue :-1 Date : - 04/11/03 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd.