Drawing : - TPC159 Issue :-4 Date : - 24/11/16 LDLD-82 DEHUMIDIFIER PROCESS DRYER (1320500) OWNER’S MANUAL www.eipl.co.
Drawing : - TPC159 Issue :-4 Date : - 24/11/16 UNPACKING Carefully remove the LD-82 dehumidifier process dryer and the Universal Controller from its transit box and visually check for signs of transit damage. If there is evidence of damage DO NOT attempt to operate the units, call your supplier for advice. Do not discard the packing; it will be useful when transporting the dehumidifier unit in the future.
Drawing : - TPC159 Issue :-4 Date : - 24/11/16 The LD-82 dehumidifier process dryer consists of a motor-compressor unit, a refrigerant condenser, air circulating fans, a refrigerated surface, and a means of collecting and disposing the condensed moisture and a cabinet to house these components. The fan draws air through the refrigerated surface and cools it below its dew point, removing moisture which is collected and led away.
Drawing : - TPC159 Issue :-4 Date : - 24/11/16 SPECIFICATIONS MODEL: LD-82 HEIGHT: 600 mm WIDTH: 315 mm DEPTH: 550 mm WEIGHT: 37 Kg AIRFLOW: 600 m3/hr OPERATING TEMP RANGE: 20-55°C POWER SUPPLY: 230V, 1 ph, 50Hz POWER (DRYING): 350W POWER (HEATING): 350W MAX WATER EXTRACTION: 13 l/24hr FINISH: epoxy coating EFFECTIVE VOLUME: 200M3 REFRIGERANT TYPE/QTY: R134a (250g) "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC159 Issue :-4 Date : - 24/11/16 INSTALLATION POSITIONING: Position the LD-82 dehumidifier process dryer in the chamber as shown and instructed (see TP 132). It is advisable to ensure that access can be made to the process drying unit even when the entire product to be dried is in place. The Universal Controller (UC-2) should also be positioned for ease of access on the outside of the chamber or adjacent wall.
Drawing : - TPC159 Issue :-4 Date : - 24/11/16 OPERATION The LD-82 dehumidifier process dryer is a basic refrigeration drying unit. A control system, the Universal Controller (UC-2), is required for each of the LD82 dehumidifier process dryers to be used in each chamber for the drying process. The operation of the LD-82 dehumidifier process dryer is to remove moisture from the air by having it condense on the cold tubes of the evaporator coil.
Drawing : - TPC159 Issue :-4 Date : - 24/11/16 WARNING: Due to the high pressures within the refrigeration circuit, under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build up of ice. • No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved.
Drawing : - TPC159 Issue :-4 Date : - 24/11/16 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON.
Drawing : - TPC159 Issue :-4 Date : - 24/11/16 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC159 Issue :-4 Date : - 24/11/16 LD-82 SPARE PARTS LIST Product Part Number PART NUMBER 1320500 Compressor 3022142 Compressor OH Protector 3021529 Compressor Start Relay 3021530 Compressor Start Capacitor 3021531 Condenser Coil 3020740 Evaporator Coil 2320515 Filter Dryer 3020937 Fan Motor 3040214 Heater Element Protector 3031710 Heater Element 3031613 Terminal Block 3031460 3-Core Cable 3031231 7-Core Cable 3031219 2µF Capacitor 3036320 Condensate Drain Tube 3
Drawing : - TPC159 Issue :-4 Date : - 24/11/16 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Drawing : - TPC159 Issue :-4 Date : - 24/11/16 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.