Drawing : - TPC304 Issue :-8 Date : - 10/12/13 K100P DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 K100P PACKAGE CONTENTS Item Description Quantity 10241HZ-US Dehumidifier 1 off 3086144 Quick release hose coupling 1 off 3944110 PVC Tube – 3/8” I/D 7.
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 INTRODUCTION Dehumidifiers remove moisture from the air that is circulating through the unit. The resulting reduction of relative humidity helps prevent rust, rot, mold, mildew and condensation within the room, or other enclosed spaces where the dehumidifier is used.
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 SPECIFICATIONS MODEL: 10241HZ-US HEIGHT: 17” (431mm) WIDTH: 28” (711mm) DEPTH: 18” (457mm) WEIGHT: 138 Lbs (62Kg) AIRFLOW: 700 CFM (1190 M3/Hr) POWER SUPPLY: 110V 1Ph 60Hz POWER 1090 W (max) FINISH: Epoxy coated steel REFRIGERANT TYPE/QTY: OPTIONAL EXTRAS: 10241HZ-US – R407C (540g) 10241HC-US - R407C (540g) • Trolley • Wall Mount Bracket "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol.
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 INSTALLATION POSITIONING: Position the dehumidifier unit in the center of the room to be conditioned if at all possible. However if a damp patch is particularly apparent the outlet grille should be pointed towards it. NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have clear space around them and not be obstructed in anyway. WIRING: Connect the power mains cable to a designated 30 Amp breaker.
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 OPERATION The operation of the dehumidifier is to remove moisture from the air by having it condense on the cold tubes of the evaporator coil. The air then passes over the hot condenser coil and returns to the conditioned space slightly warmer and dryer than when it entered the dehumidifier unit. To concentrate drying all doors and windows should be kept closed.
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 Discharge Pump The pump works automatically and periodically pumps away collected moisture to a drain or container. The pump is capable of discharging water to a vertical height of 20ft. Indicator Panel The K100P is fitted with an indicator lamp to show when power is available and the unit is switched on, if this does not appear to be functioning correctly then refer to the repairs section. Warnings.
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENACE ON ITEMS 1, 2, 3, AND 4. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: Removal of the cover is achieved by means of four screws at the sides of the unit at base level. With the cover removed all maintenance can be carried out. 1.
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the correct replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any licensed refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 TROUBLESHOOTING SYMPTOM CAUSE REMEDY 1. Tighten fan 2. Replace the fan motor 3. See Routine Maintenance Section 4. Check the wiring diagram to find fault and repair 1. Check all of the above 2. Contact the Factory Service Center 3. Contact the Factory Service Center 1. Contact the Factory Service Center 2. Contact the Factory Service Center Little or no airflow 1. Loose fan on shaft 2. Fan motor burnt out 3. Dirty refrigeration coils 4.
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 K100P SPARE PARTS LIST NUMBER DESCRIPTION PART NUMBER QUANTITY 1 DEFROST TIMER 1600500 1 2 CAPILLIARY TUBE .047 2pcs.
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 Page 13 of 16
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 Page 14 of 16
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 Page 15 of 16
Drawing : - TPC304 Issue :-8 Date : - 10/12/13 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.