INSTALLATION
POSITIONING:
Position the dehumidifier unit in the center of the room to be conditioned if at
all possible. However if a damp patch is particularly apparent the outlet grille
should be pointed towards it.
NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have
clear space around them and not be obstructed in anyway.
WIRING:
Connect the power mains cable to a designated 30 Amp breaker. As follows:-
For Models without plugs:-
Brown Live
Blue Neutral
Green/Yellow Earth (ground)
DRAINAGE:
The K100H has a water pump fitted as standard which is capable of
discharging the condensate water 20ft vertical lift away from the unit & 100ft
horizontal. The water can, therefore, be discharged into a drain some distance
away.