Operating Instructions

Page 4 of 20
Drawing : - TPC245
Issue : - 1
Date : - 13/10/03
The SCB 2016 was developed on the base of the long experience of Ebac in
wood drying. This SCB 2016 complies with DIN EN 60 204 (VDE 0113;
electrical equipment of industrial machinery) and EMV- guidelines.
This operating manual is intended to aid operation of the control unit and
SCB, to provide assistance in resolving any problems. See attached diagram
No. 9.
3 General information
The SCB 2016 is manufactured in accordance with general regulations and
updated to the latest technical standard. The operator must follow the given
security information only then the handling of the equipment can be done
safely.
WARNING
When this is shown in the text then only an experienced electrician is
allowed to repair.
4 Operation
4.1 Installation
Operating manual is inside the control box
With main switch Q1 you switch on L1, L2 and L3. Electricity is “onfor the
whole circuit and the Low Voltage Circuit (24 V DC).
Attention
The life of electrical motors depends on the correct voltage. Low supply
voltage will put stain on the motor and thus shorten their life. To
prevent this, the cables must be to VDE.
The earth separation clamp U2 that connects EARTH and L-(OV) 24V
transformer is stipulated by VDE. This is provided to indicate errors in the 24V
circuit
Switch on “System On" and the BC 2000 can be programmed (see operating
instructions BC2000 HT).