Drawing : - TPC376 Issue :-6 Date : - 10/12/13 ECO85 INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 ECO85 PACKAGE CONTENTS Item Description Quantity 10298GR-US Dehumidifier 1 3086144 Quick release hose coupling 1 3944110 PVC Tube – 3/8” I/D 7.
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 INTRODUCTION Designed for a wide range of applications, the ECO85 dehumidifier is a rugged, industrial unit which utilizes an energy-efficient compressor and a compact portable design to provide easy efficient drying.
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 SPECIFICATIONS MODEL: ECO85 HEIGHT: 27.5” (700mm) WIDTH: 19” (480mm) DEPTH: 15” (390mm) WEIGHT: 81 lbs (37 kg) AIRFLOW: 225CFM (381 M3/hr) EXTRACTION: 60 ppd (30 l/day) POWER SUPPLY: 110V/ 60Hz/ 1 ph FINISH: Powder-coated Epoxy OPERATING RANGE: 35°F – 100°F REFRIGERANT: R-407c "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 OPERATION The following procedures should be followed to test the CD85 for correct operation: 1. After unpacking, examine all external features to confirm damagefree shipment. Report all defects and damage at once. Connect the power cable to a grounded electrical outlet. 2. Check dehumidification process as follows: TO ENSURE CONTINUED FULL EFFICIENCY OF THE DEHUMIDIFEIR, MAINTENANCE PROCEDURES SHOULD BE PERFORMED AS FOLLOWS: A.
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTNENANCE To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air. Hold the nozzle of the air hose away from the coil to avoid damaging the fins.
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 TROUBLESHOOTING SYMPTOM CAUSE Unit inoperative 1. No power to unit Little or no airflow 1. Fan motor burnt out 2. Dirty refrigeration coils 3. Loose electrical wiring Little or no water extraction 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas Little or no defrost when required 1. Faulty timer 2. Faulty by-pass valve Unit vibrates excessively 1. Loose compressor 2. Damaged fan Water flooding inside the machine 1.
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 ECO85 SPARE PARTS LIST DESCRIPTION NUMBER PART NUMBER QUANTITY 1 Defrost Timer 1619508 1 2 Terminal Block 3031460 1 3 Capillary Tube 3014254 2 x 24” 4 Solenoid Valve 3020837 1 5 Filter Dryer 3020909 1 6 Compressor 3022198 1 7 Solenoid Coil 3030451 1 8 Capacitor 3030908 1 9 Filter 2029826 1 10 Mains Lead 3035148 1 11 3040262 1 12 Fan Motor Fan Motor Inlet Ring 3040254 1 13 Fan Motor Capacitor 3030893 1 14
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 Page 11 of 16
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 Page 12 of 16
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 Page 13 of 16
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 Page 14 of 16
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 Page 15 of 16
Drawing : - TPC376 Issue :-6 Date : - 10/12/13 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.