Drawing : - TPC 438 Issue :-1 Date : - 20/10/15 DD400P INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC 438 Issue :-1 Date : - 20/10/15 DD400P PACKAGE CONTENTS Item Description Quantity 1064RG-US Dehumidifier 1 TPC438 Manual 1 Page 2 of 12
Drawing : - TPC 438 Issue :-1 Date : - 20/10/15 UNPACKING Carefully remove the DD400P dehumidifier unit from its transit box and visually check for signs of transit damage. If there is evidence of damage DO NOT attempt to operate the unit, call your supplier for advice. Do not discard the packing, it will be useful when transporting the dehumidifier unit in the future. INTRODUCTION Dehumidifiers remove moisture from the air that is circulating through the unit.
Drawing : - TPC 438 Issue :-1 Date : - 20/10/15 SPECIFICATIONS MODEL: DD400P HEIGHT: 787mm (31”) WIDTH: 552mm (21.7”) DEPTH: 487mm (19.2”) WEIGHT: 31Kg (68.4 lbs) DRY AIRFLOW: 370 M³/HR WET AIRFLOW: 150 M³/HR POWER SUPPLY: 230V, 1 ph, 50Hz POWER 2.
Drawing : - TPC 438 Issue :-1 Date : - 20/10/15 INSTALLATION POSITIONING: The DD400P is designed for indoor use. Position the dehumidifier unit in the center of the room to be conditioned if at all possible. NOTE: Both the air inlets and outlets of the dehumidifier unit must have clear space around them and not be obstructed in anyway. DUCT CONNECTION The wet air outlet from the dehumidifier must be exhausted to outside of the room being dried by means of a suitable duct.
Drawing : - TPC 438 Issue :-1 Date : - 20/10/15 OPERATION The electrical controls are located on the front of the rear. They are: ON / OFF Switch • • 0 Dehumidifier OFF I Dehumidifier ON Digital Humidistat Setting the Digital Humidistat The Digital Humidistat is factory preset to give the optimum level of control. Only adjustment of the desired set point is required. During normal operation, the display shows the current % Relative Humidity within the space being conditioned.
Drawing : - TPC 438 Issue :-1 Date : - 20/10/15 AIR MOVING SYSTEM: The DD400P is a dual fan system with dedicated fans for the “Process” air and “Regeneration” air flows. As the air passes over the rotor, it will be heated as a result of the regeneration cycle. The air leaving the unit will be hotter than the air entering During normal operation some parts of the dehumidifier may become hot. This is normal.
Drawing : - TPC 438 Issue :-1 Date : - 20/10/15 SAFETY -WARNING♦ DO NOT ALLOW CHILDREN TO PLAY WITH OR AROUND THE UNIT. ENSURE THE UNIT IS INACCESIBLE TO CHILDREN WHEN NOT ATTENDED.
Drawing : - TPC 438 Issue :-1 Date : - 20/10/15 ROUTINE MAINTENANCE & REPAIR WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENACE. SWITCH OFF THE DEHUMIDIFIER APPROXIMATELY 15 MINUTES PRIOR TO REMOVING ANY PANELS, ALLOWING THE HEATER TO COOL DOWN To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: • We recommend that the filters are checked at least once a month.
Drawing : - TPC 438 Issue :-1 Date : - 20/10/15 IF ANY OF THE PRECEDING PROBLEMS OCCUR, CONTACT THE EBAC INDUSTRIAL PRODUCTS LTD SERVICE CENTER PRIOR TO CONTINUED OPERATION OF THE UNIT TO PREVENT PERMANENT DAMAGE.
Drawing : - TPC 438 Issue :-1 Date : - 20/10/15 SPARE PARTS LIST DESCRIPTION PART NUMBER Process Air Fan Motor 3040251 Capacitor for Process Air Fan Motor 3030835 Process Inlet Filter 2050029 Regeneration Air Fan Motor 3040250 Capacitor for Regeneration Air Fan Motor 3030834 Regeneration Inlet Filter 2064032 Drive Motor 3040259 Capacitor for Drive Motor 3030859 Pulley 3050552 Pulley Belt 3050551 PTC Heater 3031625 Overheat Protector 3477026 Desiccant Wheel 3020706 PCB Controller
Drawing : - TPC 438 Issue :-1 Date : - 20/10/15 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.