INSTALLATION
POSITIONING:
The DD200 is designed for indoor use. Position the dehumidifier unit in the
center of the room to be conditioned if at all possible.
NOTE: Both the air inlets and outlets of the dehumidifier unit must have clear
space around them and not be obstructed in anyway. For correct installation
and operation the unit inlet and outlet must have a clearance of 0.5M from all
adjacent surfaces and or structures.
DUCT CONNECTION
The wet air outlet from the dehumidifier must be exhausted to outside of the
room being dried by means of a suitable duct. All duct connections to the
dehumidifier have been designed for connections to standard size ducts.
The duct should be as short as possible to reduce the risk of condensation of
the wet air. The duct should slope downwards away from the unit to stop any
condensed water from flowing back into the unit.
The dry air outlet is also provided with a means of attaching a duct. This can
be used to direct the air towards more severe damp patches.
WIRING:
The DD200 is provided with a standard plug and is designed to operate from
a 13 Amp supply.
IMPORTANT – The wires in the mains lead are coloured in accordance with
the following code:
GREEN…………….…………EARTH
WHITE..……………………….NEUTRAL
BLACK.....…………………….LIVE
If the supply cord is damaged it must be replaced by qualified Ebac Industrial
Products Ltd personnel or other similar qualified persons in order to avoid
hazard
.
-
WARNING
-
THIS APPLIANCE MUST BE EARTHED