Drawing : - TPC445 Issue :-1 Date : - 02/12/15 CS90H INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC445 Issue :-1 Date : - 02/12/15 CS90H PACKAGE CONTENTS Item Description Quantity 10590GH-US Dehumidifier 1 3944110 PVC tube – 3/8” I/D 7.
Drawing : - TPC445 Issue :-1 Date : - 02/12/15 INTRODUCTION Designed for a wide range of applications, the CS90H dehumidifier is a rugged, industrial unit which utilizes an energy-efficient compressor and a compact portable design to provide easy efficient drying.
Drawing : - TPC445 Issue :-1 Date : - 02/12/15 SPECIFICATIONS MODEL: CS60H HEIGHT: 15.2” (386mm) WIDTH: 14” (353mm) DEPTH: 22” (564mm) WEIGHT: 84lbs (38 kg) AIRFLOW: 230 CFM (390M3/hr) POWER SUPPLY: 110V/ 60Hz/ 1 ph FINISH: Powder-coated Epoxy OPERATING RANGE: 33°F – 95°F REFRIGERANT: R-407c (15.2 oz) "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC445 Issue :-1 Date : - 02/12/15 OPERATION The following procedures should be followed to test the CS90H for correct operation: 1. After unpacking, examine all external features to confirm damagefree shipment. Report all defects and damage at once. Connect the power cable to a grounded 15 Amp electrical outlet. 2. Setting the Digital Humidistat The Digital Humidistat is factory preset to give the optimum level of control. Only adjustment of the desired set point is required.
Drawing : - TPC445 Issue :-1 Date : - 02/12/15 i. If the air temperature is below 80° F, an even coating of frost should cover the entire evaporator coil ii. If the air temperature is above 80° F, frost and/or droplets of condensed water should cover the entire evaporator coil. F. After continuous running time of approximately 55 minutes, the unit will enter “Hot Gas” defrost mode for 5 minutes and then automatically return to normal operation.
Drawing : - TPC445 Issue :-1 Date : - 02/12/15 ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTNENANCE To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air. Hold the nozzle of the air hose away from the coil to avoid damaging the fins.
Drawing : - TPC445 Issue :-1 Date : - 02/12/15 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC445 Issue :-1 Date : - 02/12/15 TROUBLESHOOTING SYMPTOM CAUSE Unit inoperative 1. No power to unit Little or no airflow 1. Fan motor burnt out 2. Dirty refrigeration coils 3. Loose electrical wiring Little or no water extraction 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas Little or no defrost when required 1. Faulty timer 2. Faulty by-pass valve Unit vibrates excessively 1. Loose compressor 2. Damaged fan Water flooding inside the machine 1.
Drawing : - TPC445 Issue :-1 Date : - 02/12/15 CS90H SPARE PARTS LIST DESCRIPTION NUMBER PART NUMBER QUANTITY 1 Defrost Timer 1619508 1 2 Filter 2013831 1 3 Condenser Coil 2059000 1 4 Evaporator Coil 2059001 1 5 Capillary Tube 3014249 2 x 30” 6 Drain Tubing 3014338 9 Feet 7 Solenoid Valve 3020837 1 8 Filter Dryer 3020901 1 9 Compressor 3022198 1 10 Defrost Relay 3030269 1 11 Solenoid Coil 3030451 1 12 Capacitor 3030908 1 13 Humidity Controller 3031530
Drawing : - TPC445 Issue :-1 Date : - 02/12/15 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing : - TPC445 Issue :-1 Date : - 02/12/15 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.