Drawing : - TPC225 Issue :-9 Date : - 17/08/18 CD35 / CD35P INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 CD35 PACKAGE CONTENTS Item Description Quantity 10186DG-US Dehumidifier 1 TPC225 Manual 1 CD35P PACKAGE CONTENTS Item Description Quantity 10186DP-US Dehumidifier 1 3086144 Quick release hose coupling 1 3944110 PVC Tube – 3/8” I/D 7.
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 INTRODUCTION Designed for a wide range of applications, the CD35 is a rugged, compact unit which incorporates its own tank for collected moisture with an automatic shutoff once the tank is fully. Offices, shops, houses, restaurants and storerooms can be protected by this simple answer to humidity control.
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 SPECIFICATIONS MODEL: Ebac CD35 / CD35P HEIGHT: 22” WIDTH: 13.5” DEPTH: 14” WEIGHT: CD35 – 57 lbs CD35P – 63 lbs AIRFLOW: 170 CFM POWER SUPPLY: 110V/ 60Hz/ 1 ph CD35 – 4 A CD35P – 5 A 1/50 HP MagneTek FAN MOTOR: Totally Enclosed ¼ HP Heavy Duty Fully COMPRESSOR: Hermetic Tecumseh CURRENT (MAX): CONTROL: Adjustable Humidistat REFRIGERANT: R-134a REF. CHARGE: 0.
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 FEATURES The Adjustable Humidistat: The adjustable humidistat enables you to maintain the required level of dryness within a room. The humidistat switches off the CD35 when the relative humidity falls to the level predetermined by the position of the humidistat control. The Water Tank: When the water tank has reached its capacity, a float mechanism will activate a microswitch lever and switch off the machine. The container-full indicator will also illuminate.
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 SPECIAL FEATURES (where fitted) CONDENSATE PUMP: The CD-35 dehumidifier unit can be fitted, either in the factory, or as retro-fit, with a condensate pump. This condensate pump will allow the unit to run unattended, with the condensate run off to a permanent drain and can be used up to 13 feet (4 meters), below the level of a permanent condensate drainage point.
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 WARNING: Due to the high pressures within the refrigeration circuit, under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build up of ice. • No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved.
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: Removal of the cover is achieved by means of four screws at the sides of the unit at base level.
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 TROUBLESHOOTING SYMPTOM CAUSE Unit inoperative 1. No power to unit Little or no airflow 1. Loose fan on shaft 2. Fan motor burnt out 3. Dirty refrigeration coils 4. Loose electrical wiring Little or no water extraction Little or no defrost when required Unit vibrates excessively 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas 4. Blocked filter dryer 1. Faulty timer 2. Faulty by-pass valve 1. Loose compressor 2.
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 CD35 SPARE PARTS LIST Part Number 1018611 1137907 2013865 2013866 2017707 2131107 2131147 3014272 3020811 3020937 3033033 3035145 3035346 3036636 3040181 3050216 1617990 2141095 3021518 3021543 3021544 3022147 3030421 3035773 2018641 1600500 3030275 2013837 Description EVAP COIL ASSY WATER CONTAINER MICROSWITCH SUPPORT MICROSWITCH LEVER HUMIDEX 7 KNOB HUMIDEX DRAIN TRAY CONDENSER COIL CAPILLIARY TUBE .
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labour required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 Page 14 of 16
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 Page 15 of 16
Drawing : - TPC225 Issue :-9 Date : - 17/08/18 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.