Manual
Page 3 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
SPECIFICATIONS
"This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The
refrigeration system is hermetically sealed.
The Global Warming Potential (GWP) of refrigerants used in products manufactured by Ebac
Industrial Products Ltd is as follows
R134a – 1300
R407c – 1610
For type and weight of refrigerant contained in this unit, please refer to the product data label"
M
ODEL
:
CD30 CD30E
H
EIGHT
:
300mm
300mm
W
IDTH
:
304mm
350mm
L
ENGTH
:
550mm
550mm
W
EIGHT
:
23 Kg
25 Kg
A
IRFLOW
:
150 M
3
/Hr 150 M
3
/Hr
P
OWER
S
UPPLY
:
240V, 1 ph, 50Hz
240V, 1 ph, 50Hz
P
OWER
360W (max)
460W (max)
F
INISH
:
grey epoxy coating grey epoxy coating
E
FFECTIVE
V
OLUME
:
85M
3
85M
3
R
EFRIGERANT
T
YPE
/Q
TY
:
R134a (170g) R134a (170g)