External Humidistat Option
The CD200 has the option of using an external humidistat remotely mounted within a room,
where available.
In the control box there is a connector that can be wired to, which will enable the use of an
external humidistat. The following steps should be carried out to enable correct operation of
the external humidistat.
Locate the control box and remove the cover, keeping screws for re-attachment
Locate the connector within the control box and remove the plug from the socket
Dismantle the plug and remove the link wire from terminals 2 & 3
Wire remote humidistat to terminals 1 & 3, ensuring wires pass through the plug back shell
Re-assemble the plug and refit to the socket on the control box
The CD200 internal humidistat will now be by-passed and the external humidistat will
control the unit.