Drawing No. :- TPC364 Issue :- 7 Date :- 10/12/13 EBAC MODEL CD200 INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632 Website www.ebacusa.
Drawing No.
Drawing No. :- TPC364 Issue :- 7 Date :- 10/12/13 UNPACKING Carefully remove the CD200 dehumidifier unit from its transit packaging and visually check for signs of transit damage. If there is evidence of damage DO NOT attempt to operate the unit, call your supplier for advice. Do not discard the packing, it will be useful when transporting the dehumidifier unit in the future. INTRODUCTION The Ebac CD200 industrial dehumidifier removes moisture from the air through the refrigeration process.
Drawing No. :- TPC364 Issue :- 7 Date :- 10/12/13 SPECIFICATIONS MODEL: Ebac CD200 HEIGHT: 32.75” (832mm) WIDTH: 29.5” (745mm) DEPTH: 17.
Drawing No. :- TPC364 Issue :- 7 Date :- 10/12/13 INSTALLATION POSITIONING: Position the dehumidifier unit in the center of the room to be conditioned if at all possible. However if a damp patch is particularly apparent the outlet grille should be pointed towards it if possible. This unit can also be used in a duct system where applicable, please see the diagrams on the following pages which identify the overall sizes of the unit and also the mounting points.
Drawing No. :- TPC364 Issue :- 7 Date :- 10/12/13 OPERATION The following procedures should be followed to test the CD200 for correct operation: 1) After unpacking, examine all external features to confirm damage-free shipment. Report all defects and damage at once. Connect the power cable to a grounded power source. 2) Install drain tubing as required (detailed in step F). Caution: Do not operate the machine without the covers for any longer than necessary.
Drawing No. :- TPC364 Issue :- 7 Date :- 10/12/13 External Humidistat Option The CD200 has the option of using an external humidistat remotely mounted within a room, where available. In the control box there is a connector that can be wired to, which will enable the use of an external humidistat. The following steps should be carried out to enable correct operation of the external humidistat.
Drawing No. :- TPC364 Issue :- 7 Date :- 10/12/13 ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENANCE ON ITEMS 1, 2, 4, 5, AND 6. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing No. :- TPC364 Issue :- 7 Date :- 10/12/13 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing No. :- TPC364 Issue :- 7 Date :- 10/12/13 TROUBLESHOOTING REMEDY SYMPTOM CAUSE Unit inoperative 1. no power to unit Little or no airflow 1. 2. 3. 4. Little or no water extraction 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas Unit vibrates excessively 1. Loose compressor mounts 2. Damaged fan Water flooding inside the machine 1. Drain pipe blocked/frozen 2.
Drawing No. :- TPC364 Issue :- 7 Date :- 10/12/13 RATING PLATE INFORMATION CD20 0 MOISTURE REMOVAL (PINTS PER 24 HOURS) @ 80F / 60% RH: RH: REFRIGERANT: VOLTAGE: POWER: PHASE: HZ: CURRENT: 130 1250 Grams 220 Volts 3.
Drawing No. :- TPC364 Issue :- 7 Date :- 10/12/13 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing No.
A B C D 6 6 157 192.3 112.5 5 445 220 5 50 AIR OUT 4 4 AIR IN 305 417.1 800 50 107.5 3 DO NOT SCALE IF IN DOUBT ASK 3RD ANGLE PROJECTION 19 9 7 3 06/07/11 09/09/11 1 2 2 2 MATERIAL DIMENSIONS IN m.m. TOLERANCES UNLESS OTHERWISE STATED 0. 1 FINISH 0.25 0.0 0.05 0.00 ANGULAR 0.5 DEGREE TITLE 1 N/A N/A 1 1/5 SHEET 1 OF 1 W DAGLISH 1018211 DRG.NO. CAD SCALE : DRAWN : CD200 DUCT FLANGE LOCATIONS AIR DIRECTION ADDED - WDA ORIGINAL COMMENTS BISHOP AUCKLAND Co.
A B C D 6 6 CONDENSATE OUTLET DUCT FLANGE 530mm WIDE X 305mm HIGH X 50mm DEEP 5 5 4 TOP VIEW OF CD200 AIRFLOW 4 POWER CORD FILTER INSERTED THIS SIDE AS REQUIRED INLET DUCT 3 21/12/10 1 AIRFLOW DATE ISS. 2 OUTLET DUCT ORIGINAL COMMENTS DO NOT SCALE IF IN DOUBT ASK TITLE 2 MATERIAL DIMENSIONS IN m.m. TOLERANCES UNLESS OTHERWISE STATED 0. 1 FINISH 0.25 0.0 0.05 0.00 ANGULAR 0.5 DEGREE BISHOP AUCKLAND Co.
Drawing No. :- TPC364 Issue :- 7 Date :- 10/12/13 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.