Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 CD100E INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 UNPACKING Carefully remove the CD100 dehumidifier unit from its transit box and visually check for signs of transit damage. If there is evidence of damage DO NOT attempt to operate the unit, call your supplier for advice. Do not discard the packing; it will be useful when transporting the dehumidifier unit in the future. INTRODUCTION Dehumidifiers remove moisture from the air that is circulating through the unit.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 SPECIFICATIONS MODEL: CD100E HEIGHT: 400mm WIDTH: 900mm DEPTH: 500mm WEIGHT: 75 Kg AIRFLOW: 510 cu.m/hr POWER 1.5Kw (max) POWER SUPPLY: 220V/240V, 1p, 50Hz/60Hz. FINISH: Vinyl Coated Steel Choice of Mobility MOBILITY: Aids – Wheels of Skid Handle REFRIGERANT TYPE/QTY: R407c (0.540Kg) "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 INSTALLATION POSITIONING: Position the dehumidifier unit in the center of the room to be conditioned if at all possible. However if a damp patch is particularly apparent the outlet grille should be pointed towards it. NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have clear space around them and not be obstructed in anyway. For correct installation and operation the unit inlet and outlet must have a clearance of 0.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 OPERATION The operation of the dehumidifier is to remove moisture from the air by having it condense on the cool tubes of the evaporator coil. The air then passes over the hot condenser and returns to the conditioned space slightly warmer and at reduced moisture content. To concentrate drying all doors and windows should be kept closed.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 WARNING: • • Due to the high pressures within the refrigeration circuit, under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build up of ice. No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 SETTING THE ADJUSTABLE HUMIDISTAT: The positioning of the humidistat depends on the application the CD100 is being used for and the conditions within the area to be dried. The following table can be used as a guide: APPLICATION HUMIDISTAT SETTING FACTORIES 60% WAREHOUSES 50% BASEMENTS 50% DEFLOODING 40% INDICATOR PANEL The CD100 is fitted with an indicator lamp to show when power is available and when the unit is switched on.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 SPECIAL FEATURES HEATED CONDENSATE DRAINAGE TUBE: The CD100E dehumidifier is fitted with a heater tape which runs the length of the condensate tube. The effect of this heated condensate drainage tube will ensure that the drainage point for the dehumidifier is kept free from ice when operated in low ambients.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 TROUBLESHOOTING SYMPTOM Unit inoperative (no red light) CAUSE 1. No power to unit REMEDY 1. Check the power supply and fuse 1. Tighten fan 2. Replace the fan motor 3. See Routine Maintenance Section 4. Check the wiring diagram to find fault and repair 1. Check all of the above 2. Contact the Factory Service Center 3. Contact the Factory Service Center 4. Contact the Factory Service Center 1. Contact the Factory Service Center 2.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 CD100E SPARE PARTS LIST DESCRIPTION PART NUMBERS 1027300 Pre Set Humidistat 3035145 Adjustable Humidistat 3035145 Compressor 3020128 Reversing Valve 3020810 Filter Dryer 3020904 Fan Motor 3030129 Solenoid Coil 3030402 Rotary Switch 3030555 Drain Tube Heater Tape 3031629 Indicator Lamp 3032203 Float Switch 3033021 Contactor 3034389 Panel Mounting Plug 3035997 Free Socket 3035998 Fan Blade 3040116 Knob 3090611 Knob Cap 3090
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 CD100 / CD100E WALL MOUNTING BRACKET KIT PART NUMBER 1027301 KIT CONTENTS: Item Qty Description 1 2 Frame Hook Rail 2 1 Frame Location Angle 3 1 Frame Top Angle 4 2 Frame Bottom Angle 5 2 ‘U’ Channel With Foot 6 2 Frame Support 7 3 3/16” Dome Head Rivet 8 10 M8 X 25mm Hex Head Screw 9 10 M8 Spring Washer 10 10 M8 Flat Washer 11 10 M8 Spring Nut and Plate 12 6 End Cap 13 1 Mounting Fame Assembly 1027301 14 1 Insta
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 5. Drill the appropriate fixing holes into Item 3 to secure bracket onto the wall. 6. Secure the bracket to the wall 7. With reference to Drawing 5060117 Position the CD100 / CD100E onto the Wall Mounted Bracket. 8. Using Item 6 assemble items 1 and 2 ensuring the fingers of Item 2 locate into the CD100 chassis. 9. Secure the CD100 / CD100E with the 2 Claw Clamps onto Item 1.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Drawing : - TPC181 Issue : - 11 Date : - 24/11/16 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.