INSTALATION
POSITIONING:
Position the dehumidifier unit in the center of the room to be conditioned if at
all possible. However if a damp patch is particularly apparent the outlet grille
should be pointed towards it.
NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have
clear space around them and not be obstructed in anyway. For correct
installation and operation the unit inlet and outlet must have a clearance of
0.5M from all adjacent surfaces and or structures.
WIRING:
Connect the power mains cable to a 13 Amp power supply. As follows:-
Brown Live
Blue Neutral
Green/Yellow Earth (ground)
DRAINAGE:
Connect a 15mm inside diameter hose to the water outlet pipe. Secure the
hose using a worm drive clip. The hose should at no point be raised higher
than the outlet pipe. Failure to observe this requirement will result in flooding
of the dehumidifier unit.