Drawing : - TPC481 Issue :-1 Date : - 14/06/18 BKool12 PORTABLE ACU OWNER’S MANUAL www.eipl.co.
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 INTRODUCTION Heat is a form of energy, cooling is means of transfering the heat from one object to another. In the case of Air conditioning, sensible heat is removed from the indoor space and replaced with cooler air, and the warm air removed is exhausted outside the space being conditioned. This process gradually reduces / maintains the inside temperature.
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 SPECIFICATIONS MODEL: 102970GB-GB COOLING CAPACITY 12000 BTU (@27°C / 60% RH) HEIGHT: 1130mm WIDTH: 500mm DEPTH: 675mm WEIGHT: 88 kg EVAPORATOR AIRFLOW: 640 M3/Hr EVAPORATOR OUTLET DIA: 2 X 100mm CONDENSER AIRFLOW: 1900 M3/Hr CONDENSER OUTLET DIA: 310mm SOUND LEVEL: 69.
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 INSTALLATION POSITIONING: Position the ACU unit in the center of the room to be conditioned if at all possible. However, if a specific area needs to be cooled then place the unit and the cool air outlets over these areas. NOTE: all air inlets and all air outlets of the ACU unit must have clear space around them and not be obstructed in anyway. For correct installation and operation the unit must have a clearance of 0.
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 OPERATION The following procedures should be followed to test the BKool12 for correct operation: 1. After unpacking, examine all external features to confirm damage-free shipment. Report all defects and damage at once. Connect the power cable to a grounded 13 Amp electrical outlet. 2. Setting the Digital Thermostat The Digital thermostat is factory preset to give the optimum level of control. Only adjustment of the desired set point is required.
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 defrost light will illuminate. Once defrost is achieved the unit will return to normal operation. If, after carrying out the above procedures, the unit does not appear to function properly, refer to the Trouble Shooting section, which follows, or contact the Factory Service Centre. CAUTION: ONCE THE UNIT HAS BEEN SWITCHED OFF, WAIT AT LEAST FIVE MINUTES BEFORE RESTARTING. DRAINAGE The ACU unit has a removable water collection container.
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 disconnected from the power supply. Then contact either the manufacturer, distributor or qualified personnel. Warnings. • Due to the high pressures within the refrigeration circuit, under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build up of ice. • No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved.
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON. To ensure continued full efficiency of the ACU unit, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a Refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 TROUBLESHOOTING SYMPTOM Unit inoperative Little or no airflow Little or no defrost when required Unit vibrates excessively Water flooding inside the machine CAUSE REMEDY 1. Check the power from 1. No power to unit power supply panel 1. Replace the fan motor 1. Fan motor burnt out 2. See Routine Maintenance 2. Dirty refrigeration coils / Section filter 3. Check the wiring diagram to 3. Loose electrical wiring find fault and repair 1.
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 BKool12 SPARE PARTS LIST NUMBER DESCRIPTION PART NUMBER QUANTITY 1 Timer 2 Evaporator Coil 2097046 1 3 Condenser Coil 2097047 1 4 Evaporator Fan 3040280 1 5 Condenser Fan 3040329 1 6 Compressor 3944944 1 7 Capillary 3014249 2 x 4ft 8 Filter Dryer 3020957 1 9 Low pressure stat 3021155 1 10 High pressure stat 3021153 1 11 Frostat 3031516 1 12 Relay 3030270 1 13 Temperature Controller 3031522 1 14 Temperature
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 Page 13 of 16
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 Page 14 of 16
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 Page 15 of 16
Drawing : - TPC481 Issue :-1 Date : - 14/06/18 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.