Brochure
St Helen Trading Estate, Bishop Auckland, Co. Durham. DL14 9AD
Tel: 01388 664400 Fax: 01388 662590 Email: sales@eipl.co.uk www.eipl.co.uk
BKool12 16 & 24
ApplicAtions:
Applications
Offices
Computer Server Room
Workshops
Warehouses
Manufacturing Processes / Facilities
Marquees / Special Events
Temporary Cooling During Plant Maintance
specificAtions:
BKool12 BKool16 BKool24
Specication 10970GB-GB 10971GB-GB 10972GB-GB
Height (mm) 1130 1180 1280
Width (mm) 500 500 500
Depth (mm) 675 675 740
Weight (kg) 88 92 103
Voltage (V) 230 230 230
Power (kW) 1.7 2.3 3.0
Current (A) 7 10 13
Supply Fuse Rating (A) 13 13 13
Cooling Capacity @ 27°C/60% (BTU) 12,000 16,000 24,000
Evaporator Airflow (m3/hr) 640 640 950
Max Evap Static Pressure (mm/wg) 63 63 63
Condenser Airflow (m3/hr) 1900 1900 1900
Max Cond Static Pressure (mm/wg) 112 112 112
Refrigerant R407c R407c R407c
Water Container Capacity (lts) 4 4 4
Cool Air Outlets - Qty / Dia (mm) 2 / 100 2 / 100 2 / 100
Sound Level (dbA) 70 72 72
Duct Diameter (mm) 310 310 310
Operating Conditions - Min/Max (°C) 18 - 35 18 - 35 18 - 35
feAtures:
BKool12 BKool16 BKool24
Features 10970GB-GB 10971GB-GB 10972GB-GB
On/Off Control
4 4 4
Electronic Thermostat
4 4 4
Air Inlet Filter
4 4 4
High Pressure Cutout
4 4 4
Low Pressure Cutout
4 4 4
Bucket Fitted / Full Switches
4 4 4
Castors
4 4 4
Ductable Warm Air
4 4 4
Flexiable Directional Outlets
4 4 4
Condensate Pump Option
4 4 4
eipl 44+ YeArs of proVen eXperiAnce
EIPL have for many years designed and manufactured bespoke Air
Conditiong systems for the Military and Rail markets. Customers
include:- BAE Systems, AirBus, Alstom, Bombardier and many
more. The key requirement when designing for these markets is
robustness and reliability. This experience has now been used to
develop a range of Spot Coolers aimed towards the commercial /
Industrial markets.
principAl of Air conditioning
Heat is a form of energy, cooling is means of transfering the heat
from one object to another. In the case of Air conditioning, sensible
heat is removed from the indoor space and replaced with cooler air,
and the warm air removed is exhausted outside the space being
conditioned. This process gradually reduces / maintains the inside
temperature. Air Conditioning is most commonly used to achieve
a more comfortable interior environment, typically for humans or
animals. However, air conditioning is also used to cool rooms filled
with heat-producing electronic items, such as computer server
rooms. Spot Coolers allow the cool air to be directed towards
specific objects or people.
eipl BKool rAnge
The EIPL range of Bkool Spot coolers have been sized to
provide cooling for all sized applications. All units are powered
from a regular 230V domestic supply available in all properties.
The self contained, “plug and play” equipment allows easy
installation, just connect a suitable duct to the outlet and
position, preferable outside, alternatively outside the space to
be cooled, connect to a suitable power source and adjust the
digital thermostat to the desired temperature.
As the BKool Spot Cooler cools the air, moisture is also
removed. This water is collected in the internal container,
alternatively the container can be changed for a high capacity
internal condensate pump, allowing the unit to run for long
periods unattended.
Safety is always an important consideration with EIPL,
therefore the BKool range incorporates both High and Low
Pressure stats which prevent the unit from running in unsafe
conditions.
The large diameter robust castors allow the unit to be easily
manoeuvred into positioned, and the brake applied to prevent
movement during operation.