Drawing : - TPC161 Issue :-5 Date : - 09/12/13 BD-150 (1024500) INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC161 Issue :-5 Date : - 09/12/13 INTRODUCTION Designed for a wide range of applications, the BD-150 dehumidifier is a super high capacity industrial unit which provides fast and efficient drying.
Drawing : - TPC161 Issue :-5 Date : - 09/12/13 SPECIFICATIONS MODEL: BD-150 HEIGHT: 36” WIDTH: 24” DEPTH: 24” WEIGHT: 146 lb AIRFLOW: 650 CFM POWER SUPPLY: 110V/ 60Hz/ 1 ph FINISH: Powder-coated Epoxy OPERATING RANGE: 33°F – 95°F REFRIGERANT: R-407c (19 oz) "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC161 Issue :-5 Date : - 09/12/13 OPERATION The following procedures should be followed to test the BD-150 for correct operation: 1. After unpacking, examine all external features to confirm damagefree shipment. Report all defects and damage at once. Connect the power cable to a grounded 15 Amp electrical outlet. Connect a 12.5 mm inside diameter hose to the condensate outlet pipe (positioned centrally, beneath the air inlet grille). Secure the hose using a worm drive clip.
Drawing : - TPC161 Issue :-5 Date : - 09/12/13 ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTNENANCE To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Replace or clean the inlet air grille as required. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC161 Issue :-5 Date : - 09/12/13 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC161 Issue :-5 Date : - 09/12/13 TROUBLESHOOTING SYMPTOM CAUSE Unit inoperative 1. No power to unit Little or no airflow 1. Loose fan on shaft 2. Fan motor burnt out 3. Dirty refrigeration coils 4. Loose electrical wiring Little or no water extraction 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas Little or no defrost when required 1. Faulty timer 2. Faulty by-pass valve Unit vibrates excessively 1. Loose compressor 2.
Drawing : - TPC161 Issue :-5 Date : - 09/12/13 BD-150 SPARE PARTS LIST NUMBER 1 DESCRIPTION Compressor (AK5512E) PART NUMBER QUANTITY 3020116 1 Compressor Overheat 2 Protector 3031728 1 3 Compressor Capacitor 3036337 1 4 Condenser Coil 3020727 1 5 Evaporator Coil 3020732 1 6 Filter Dryer 3020904 1 7 Fan Motor Assembly 3035774 1 8 By-pass Valve 3020810 1 9 Electronic Timer 1600500 1 10 Rotary Switch 3030555 1 11 Terminal Block 3031460 1 12 Solenoid Coil 3030
Drawing : - TPC161 Issue :-5 Date : - 09/12/13 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labour required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing : - TPC161 Issue :-5 Date : - 09/12/13 Page 10 of 12
Drawing : - TPC161 Issue :-5 Date : - 09/12/13 Page 11 of 12
Drawing : - TPC161 Issue :-5 Date : - 09/12/13 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.