BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL Drawing : - TPC337 Issue : - 4 Date : - 24/11/16
UNPACKING room, or other enclosed space where the dehumidifier is used. Thank you for deciding to purchase an EIPL Industrial dehumidifier. Like the many tens of thousands of people who have already bought an EIPL dehumidifier we are confident you will find it is the most effective answer to the problem of condensation and dampness related problems.
OPERATION The fan draws moist air through the refrigerated surface which cools it below it’s dew point, removing moisture which is collected and lead away. The cool air then passes over the hot condenser, where it is reheated. With the addition of other radiated heat the air is discharged into the room at a higher temperature but a lower relative humidity than when the air entered the unit.
BASIC STEPS FOR DRYING Ensure that all EXTERNAL doors and windows are CLOSED. Where no doors or windows are fitted, temporarily screen off the openings. POSITIONING For small areas position centrally in the area to be dried. For larger areas such as open plan buildings, offices, factories, a number of dryers may be required, in such cases they should be spread evenly around the area. Ensure that no unit is positioned in such a way that it blows directly into another.
SPECIAL FEATURES DEFROST OPERATION If the ambient temperature of the room in which the dehumidifier is conditioning, falls below 15°C ice will form on the evaporator coil as air passes over it. Over a period of time this build up of ice will effect the efficiency of the dehumidifier on it’s ability to maintain the required set conditions within the room. The BD150 is therefore fitted with a defrost control device. This defrost control device is timed to operate every 42 minutes for a period of 4 minutes.
SAFETY • • • • • • • • • • • • DO NOT USE THE UNIT IF THE CABINET OR POWER CORD IS DAMAGED. DO NOT INSERT OBJECTS INTO ANY OF THE GRILLES ON THE MACHINE. DO NOT COVER OR OBSTRUCT AIRFLOW FROM THE GRILLES DO NOT OPERATE THE UNIT WITH THE COVERS REMOVED. DO NOT ATTEMPT ANY REPAIRS SHOULD THE UNIT FAIL TO OPERATE. DO NOT STAND ON THE UNIT. DO NOT ATTEMPT TO LIFT HEAVY UNITS UN ASSISTED.
TECHNICAL SPECIFICATION Height: Width: Depth: Weight: Airflow: Voltage: Phase: Frequency: Maximum Power: Maximum Current: Generator Size: Fuse Rating: Effective Volume: Refrigerant Type: Refrigerant Quantity: Normal Extraction: Maximum Extraction: Noise Level: Finish: Mobility: 1021800 1021900 UK UK 915 915 610 610 692 692 80 75 510 510 230/110 230 1 1 50 50 1.5 1.5 8/16 8 1.5 1.5 13 13 300 300 R407c R407c 0.54 0.
WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str. 29-37 Gebäude 35 D-13599, Berlin Germany Tel: +44 (0) 1388 664400 Fax: +44 (0) 1388 662590 Tel: +01 757 873 6800 Fax: +01 757 873 3632 Tel: +49 3043 557241 Fax: +49 3043 557240 www.eipl.co.