Drawing : - TPC449 Issue :-2 Date : - 02/11/16 INTRODUCTION Dehumidifiers remove moisture from the air that is circulating through the unit. The resulting reduction of relative humidity helps prevent rust, rot, mold, mildew and condensation within the room, or other enclosed spaces where the dehumidifier is used.
Drawing : - TPC449 Issue :-2 Date : - 02/11/16 SPECIFICATIONS MODEL: 10185GH-GB HEIGHT: 692mm WIDTH: 580mm DEPTH: 464mm WEIGHT: 53 kg AIRFLOW: 510 M3/Hr POWER SUPPLY: 230V - 50Hz - 1 ph FINISH: Powder-coated Epoxy OPERATING RANGE: 3°C – 35°C REFRIGERANT: R407c (540g) "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC449 Issue :-2 Date : - 02/11/16 INSTALLATION POSITIONING: Position the dehumidifier unit in the center of the room to be conditioned if at all possible. However if a damp patch is particularly apparent the outlet grille should be pointed towards it. NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have clear space around them and not be obstructed in anyway. For correct installation and operation the unit must have a clearance of 0.
Drawing : - TPC449 Issue :-2 Date : - 02/11/16 OPERATION The following procedures should be followed to test the K100H for correct operation: 1. After unpacking, examine all external features to confirm damagefree shipment. Report all defects and damage at once. Connect the power cable to a grounded 13 Amp electrical outlet. 2. Setting the Digital Humidistat The Digital Humidistat is factory preset to give the optimum level of control. Only adjustment of the desired set point is required.
Drawing : - TPC449 Issue :-2 Date : - 02/11/16 i. If the air temperature is below 25°C, an even coating of frost should cover the entire evaporator coil ii. If the air temperature is above 25°C, frost and/or droplets of condensed water should cover the entire evaporator coil. F. After continuous running time of approximately 55 minutes, the unit will enter “Hot Gas” defrost mode for 5 minutes and then automatically return to normal operation.
Drawing : - TPC449 Issue :-2 Date : - 02/11/16 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC449 Issue :-2 Date : - 02/11/16 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a Refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC449 Issue :-2 Date : - 02/11/16 TROUBLESHOOTING SYMPTOM Unit inoperative Little or no airflow Little or no water extraction Little or no defrost when required Unit vibrates excessively Water flooding inside the machine CAUSE REMEDY 1. Check the power from 1. No power to unit power supply panel 1. Tighten fan 1. Loose fan on shaft 2. Replace the fan motor 2. Fan motor burnt out 3. See Routine Maintenance 3. Dirty refrigeration coils / Section filter 4. Check the wiring diagram to 4.
Drawing : - TPC449 Issue :-2 Date : - 02/11/16 K100H SPARE PARTS LIST NUMBER DESCRIPTION PART NUMBER QUANTITY 1 Timer 1619508 1 2 Evaporator Coil 3020732 1 3 Condenser Coil 3020727 1 4 Fan Blade 3040116 1 5 Capillary Tube 3014251 2 X 48” 6 Solenoid Valve 3020833 1 7 Filter Dryer 3020957 1 8 Compressor 3944914 1 9 Solenoid Coil 3030454 1 10 Capacitor 3037505 1 11 Fan Motor 3030129 1 12 Contactor 3930733 1 13 Pump 3160148 1 14 Digital Humidistat 3031
Drawing : - TPC449 Issue :-2 Date : - 02/11/16 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Drawing : - TPC449 Issue :-2 Date : - 02/11/16 UK Head Office American Sales Office German Sales Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Ebac Industrial Products Ltd. Gartenfelder Str.