User Manual
GB
- 21 -
10. Charger indicator
 Indicator status
 Explanations and actions
 Red LED  Green LED
 O ff Flashing   Ready for use
The charger is connected to the mains and is ready for use; there is no 
battery pack in the charger
 On  Off  Charging
The charger is charging the battery pack in quick charge mode.
 O ff   On The battery pack is fully charged (charging completed)
Action: 
Take the battery pack out of the charger. Disconnect the charger from 
the mains supply.
 Flashing  Off  Adapted charging
The charger is in gentle charging mode. For safety reasons the char-
ging is performed less quickly and takes more than 1 hour. The rea-
sons can be: 
-  The battery pack has not been used for a very long time or an alrea-
dy fl at battery was further discharged (exhaustive discharge) 
-  The battery pack temperature is outside the ideal range (between 
10° C and 45° C).
Action: 
Wait for the charging to be completed; you can still continue to charge 
the battery pack.
Flashing Flashing Fault
Charging is no longer possible. The battery pack is defective.
Action: 
Never charge a defective battery pack. Take the battery pack out of the 
charger.
 On  On Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold 
(below 0° C).
Action: 
Remove the battery pack and keep it at room temperature 
(approx. 20° C) for one day.
Anl_TC_CD_12_Li_SPK9.indb 21Anl_TC_CD_12_Li_SPK9.indb 21 08.04.2021 13:32:1208.04.2021 13:32:12