10. Troubleshooting
Fault Possible cause Remedy
Pump does not
cut in
- Power failure
- Pump not switched on
- No transport fl uid is being dischar-
ged, the output line is adequately
pressurized
- Check the cable and fuse
- Switch on pump
- Open consumer
Pump cuts out and
in constantly
- Output side leaking - Check consumers and output line
for leaks
Pump does not cut
out
- Output side leaking
- Consumer open
- Check consumers and output line
for leaks
- Close consumer