7. Replacing the power cable
If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.
8. Maintenance
The flow switch requires no maintenance. The only
requirement is for regular checks on the screw
connections and line to ensure that they are correctly
positioned, secure and not leaking so that error
sources can be identified and rectified as soon as
possible.
9. Ordering replacement parts
Please quote the following data when ordering
replacement parts:
앬 Type of machine
앬 Article number of the machine
앬 Identification number of the machine
앬 Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
Fault Possible cause Remedy
Pump does not cut in Power failure Check the cable and fuse
Pump not switched on Switch on pump
Pump cuts out and in constantly Output side leaking Check consumers and output line
for leaks
Pump does not cut out Output side leaking Check consumers and output line
for leaks
Consumer open Close consumer
Pump does not cut in No transport fluid is being
discharged, the output line is
adequately pressurized
Open consumer
10. Troubleshooting