User Manual
GB
- 16 -
10. Troubleshooting
 If the equipment is operated properly you should experience no problems with malfunctions or faults. 
In the event of any malfunctions or faults, please check the following before you contact your customer 
services.
 Fault Possible cause Remedy
 Overload  cut-out 
trips
 - Charger clamps connected incor-
rectly
-  Contact between the charger 
clamps
-  Battery highly discharged
- Battery defective
 - Connect the red clamp to the posi-
tive pole and the back clamp to the 
bodywork
- Prevent contact
-  Select a lower charging current
-  Have the battery checked by an 
expert and replace it if necessary
Charging current 
indicators does not 
work
 - Poor contact between the charger 
clamps and battery poles 
- Battery defective
-  Defective charging current indicator
 - Clean the contacts and charger 
clamps
-  Have the battery checked by an 
expert and replace it if necessary
-  Check the function of the equip-
ment using a diff erent battery
Anl_CC_BC_22_E_SPK1.indb 16Anl_CC_BC_22_E_SPK1.indb 16 01.03.16 10:3301.03.16 10:33