Use and Care Manual

EN
- 13 -
Wear ear-muff s.
The impact of noise can cause damage to
hearing.
Reduce noise generation and vibration to a
minimum!
•
Use only equipment that is in perfect
condition.
•
Maintain and clean the equipment regularly.
•
Adapt your way of working to the equipment.
•
Do not overload the equipment.
•
Have the equipment checked if necessary.
•
Switch off the equipment when not in use.
•
Wear gloves.
CAUTION!
Residual risks
Even if you use this electric power tool in
accordance with the instructions, certain
residual risks cannot be eliminated. The
following hazards may arise in connection
with the equipment‘s construction and
layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear
protection is applied.
3. Health damage caused by hand-arm
vibrations if the equipment is used over a
longer period or is not properly guided and
maintained.
Limit the operating time.
All stages of the operating cycle must be
considered (for example, times in which the
electric tools are switched off and times in which
the tool is switched on but operates without load).
5. Before starting the equipment
Be sure to read the following information before
you put the cordless impact drill into operation:
1. Charge the battery pack only with a charger
from the Power-X-Change series.
2. Only ever use sharp drill bits and screwdriver
bits which are suitable for the purpose and in
faultless condition.
3. Using a cable/pipe detector, check the area
you want to work on for concealed electric
cables and gas and water pipes.
5.1. Inserting a tool (Fig. 6)
Important! Set the changeover switch (3) to its
center position whenever you carry out any work
(for example changing the tool, maintenance
work, etc.) on the equipment.
•
Clean the tool before fitting it and apply a thin
coating of bit grease to the tool shaft.
•
Turn and push the dust-free tool into the tool
mounting (5) as far as it will go. The tool will
lock automatically.
•
Check that the bit is locked in placed by
pulling on it.
5.2. Removing a tool (Fig. 7)
Pull back and hold the locking sleeve (1) and
remove the tool.
6. Operation
6.1 Selector switch for driving/drilling/impact
drilling (Fig. 3/Item 2)
Caution!
Change the switch position only when the
equipment is at a standstill!
Drilling/screwdriving:
For drilling/screwdriving, press the button (6) on
the selector switch (2) and simultaneously turn
the selector switch (2) to switch setting A.
Hammer drilling:
For hammer drilling, press the button (6) on the
selector switch (2) and simultaneously turn the
selector switch (2) to switch setting B.
Important!
You need apply only slight contact pressure for
impact drilling. Excessive contact pressure will
place unnecessary strain on the motor. Check drill
bits at regular intervals. Sharpen or replace blunt
drill bits.
6.2 Changeover switch (Fig. 4/Item 3)
Using the changeover switch (3) above the On/Off
switch (4) you can select the direction of rotation
of the equipment and lock the equipment so that
it cannot be switched on accidentally. You can
select between clockwise and counter-clockwise
rotation. To avoid causing damage to the gearing,
the direction of rotation must only be changed
when the equipment is at a standstill. When the
changeover switch (3) is in the middle position,
Anl_TE_HD_18_Li_SPK7_USA.indb 13Anl_TE_HD_18_Li_SPK7_USA.indb 13 23.04.2019 11:14:2623.04.2019 11:14:26