Owner`s manual

88
Chapter 8 Network capture functions
Parameter set up
Click Parameter set up button and setup the parameters on the Parameter setup window.
Items Description
Capture port ............... Sets the capture port no. on the projector. Default is 9000.
Pincode ......................... Sets the Network PIN code on the projector.
PJ search time ............. Sets the time to search the projector between 1 to 60 seconds. Default is 5 seconds.
q Select normal network adapter
Uses default setting. Default is un-checked.
q Auto-power on ...... The projector turns on and projects the computer's captured image on the screen
automatically when the network capture is executed while the projector is in the standby.
Select capturing object
.... Check if you want to select an individual window on the computer screen. This is useful
function when you open the multiple windows on the computer's screen. When you
execute the capturing, the window selection dialog appears. Select a window name
from the dialog window. The projected window size is automatically adjusted to fit the
projector's screen size.
Sharpness..................... Select a capturing picture
quality among "High,
"Medium", "Low"
Reduc
e image ............. Check if the capturing
image resolution is more
than projector's panel
resolution (XGA),
Capture start up time
...... Sets the delayed time from
the capture start in second.
To check the Capture Port number, see item "Control by the web browser" ( p.91). To check the PIN code, see item
"Network PIN code setting" ( p.30, p.39).
Specify
the port number of TCP/IP. The default port setting is 9000. There are some reserved port numbers and also
some applications may use their own port numbers. If one of those port numbers is used, the alert dialog window
will appear and let you know that it is an invalid port number. In that case, use another port number.
T
he reserved port numbers are http (80), ftp (21), telnet (23), (25), (110), etc. The port no. 4352, 10000, 10001 are
r
eserved to control the projector through the LAN port.
The "Parameter set up" can not be operated during the real time capturing.