Service manual

-41-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
2 Fan1 Speed Gain
Additional Fan Speed of Min at Lamp Voltage
Down (unit: 0.1V)
0-255
3 Fan2 Speed Gain 0-255
4 Fan3 Speed Gain 0-255
5 not used 9999 0-255
Group 257 Fan Dimmer Setting
0 Dimmer Average Check Period
Dimmer Avarage measurement Time
(0:10sec, 1:30sec, 2:6sec, 90sec...10:300sec)
1 0-10
1 Dimmer Average Dimmer Avarage Value (Read only) -
2 Last Voltage Difference -
3 Voltate Difference Goal
Group 258 Fan IC Temp for Netowrk model
0 Standby Cooling Check Cycle Temp A check cycle at Standby
1 Standby Cooling Start Threshold Cooling start threshold temp A
2 Standby Cooling Enable Cooling in standby Ebable
Group 260 Auto Calibration (Commn) * Auto Calibration
0 Execute Calibration 0 0 - 1
Executes Auto-Calibration when changiing
the Value (PC White 100%)
1 Loop Count Maximum Execution Times (OFFSET->GAIN) 10 1 - 30
2 Auto Status Result of Auto-Calibration (Last Memory) 0 0 / 1 / 9 0: OK, 1: Adjusting,9: Error * ReadOnly
3 AutoWait Wait Value for each setting 1 1 - 20
4 CHECK -Tolelance Torelance of OFFSET 2 1 - 255
Group 261 Auto Calibration (RGB)
0 OFFSET AREA H START Black Level Acquiring Area H-Start Position 975 0 - 1000
1 OFFSET AREA V START Black Level Acquiring Area V-Start Position 500 0 - 1000
2 GAIN AREA H START White Level Acquiring Area H-Start Position 25 0 - 1000
3 GAIN AREA V START White Level Acquiring Area V-Start Position 500 0 - 1000
4 Image AREA H WIDTH Black/White Level Acquiring Area 13 0 - 4095
5 Image AREA V HIGHT Black/White Level Acquiring Area Height 9 0 - 4095
6 OFFSET target Target Value of Black Level Adj. 3 0 - 127
7 OFFSET torelance Torelance of Black Level Adj. 1 1 - 127
8 GAIN target Target Value of White Level Adj. 238 0 - 255
9 GAIN torelance Torelance of White Level Adj. 1 1 - 255
Group 262 Auto Calibration (CVBS/SVIDEO)
0 Y Image Area Start X Y Acquiring Area H-Start Position 20 0 - 1000
1 Y Image Area Start Y Y Acquiring Area V-Start Position 500 0 - 1000
6 Image Area H Width Image Level Acquiring Area 13 0 - 4095
7 Image Area V Hight Image Level Acquiring Area Height 20 0 - 4095
8 Y Target Level Target Value of Y Level Adj. 217 0 - 255
11 Gain Tolerance Torelance of Level Adj. 1 0 - 255
12 Delta Gain Deviation Width of Gain Value 9 0 - 255
Group 264 Auto Calibration (YCbCr)
0 Y-OFFSET AREA H START Y - Offset Acquiring Area H-Start Position 925 0 - 1000
1 Y-OFFSET AREA V START Y - Offset Acquiring Area V-Start Position 500 0 - 1000
2 CB - OFFSET AREA H START CB - Offset Acquiring Area H-Start Position 925 0 - 1000 If not used: use Y's value
3 CB - OFFSET AREA V START CB - Offset Acquiring Area V-Start Position 500 0 - 1000 If not used: use Y's value
4 CR - OFFSET AREA H START CR - Offset Acquiring Area H-Start Position 925 0 - 1000 If not used: use Y's value
5 CR - OFFSET AREA V START CR - Offset Acquiring Area V-Start Position 500 0 - 1000 If not used: use Y's value
6 Y - GAIN AREA H START Y 50 0 - 1000
7 Y - GAIN AREA V START 500 0 - 1000
8 CB - GAIN AREA H START 800 0 - 1000
9 CB - GAIN AREA V START 500 0 - 1000
10 CR - GAIN AREA H START 700 0 - 1000
11 CR - GAIN AREA V START 500 0 - 1000
12 Image AREA H WIDTH YCBCR Level Acquiring Area 8 0 - 4095
13 Image AREA V HIGHT YCBCR Level Acquiring Area Height 9 0 - 4095
14 Y - OFFSET TARTGET 4 0 - 255
15 CB OFFSET TARGET 128 0 - 255
16 CR OFFSET TARGET 128 0 - 255
17 Y - GAIN TARGET 217 0 - 255
18 CB - GAIN TARGET 237 0 - 255
19 CR - GAIN TARGET 237 0 - 255
20 OFFSET torelance Torelance of OFFSET Adj. 1 1 - 255
21 GAIN torelance Torelance of GAIN Adj. 1 1 - 255
Group 280 AutoPC Adjsut
0 AutoPCAdjustEnable
Auto-PC Adj Operation Enable if Un-
supported Signal Input
0 0 - 1 0: Enable, 1: Disable
1 Frequency Step Frequency Steps of TotalDot 1 0-3
2 Frequency Threshold Total Dot Freqency Threshold 5 0 - 10 0 [] <--- -----> 10[Not matched]