Service manual

-39-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
4 DIMMER_CTRL_LEVEL5
Luminance Level 5 Data for Dimmer: Dim
Level 5 at the less than the Value
0 - 255
5 DIMMER_CTRL_LEVEL6
Luminance Level 6 Data for Dimmer: Dim
Level 6 at the less than the Value
0 - 255
6 DIMMER_CTRL_LEVEL7
Luminance Level 7 Data for Dimmer: Dim
Level 7 at the less than the Value
0 - 255
7 DIMMER_CTRL_LEVEL8
Luminance Level 8 Data for Dimmer: Dim
Level 8 at the less than the Value
0 - 255
8 DIMMER_CTRL_LEVEL9
Luminance Level 9 Data for Dimmer: Dim
Level 9 at the less than the Value
0 - 255
9 DIMMER_CTRL_LEVEL10
Luminance Level 10 Data for Dimmer: Dim
Level 10 at the less than the Value
0 - 255
10 DIMMER_CTRL_LEVEL11
Luminance Level 11 Data for Dimmer: Dim
Level 11 at the less than the Value
0 - 255
11 DIMMER_CTRL_LEVEL12
Luminance Level 12 Data for Dimmer: Dim
Level 12 at the less than the Value
0 - 255
12 DIMMER_CTRL_LEVEL13
Luminance Level 13 Data for Dimmer: Dim
Level 13 at the less than the Value
0 - 255
13 DIMMER_CTRL_LEVEL14
Luminance Level 14 Data for Dimmer: Dim
Level 14 at the less than the Value
0 - 255
14 DIMMER_CTRL_LEVEL15
Luminance Level 15 Data for Dimmer: Dim
Level 15 at the less than the Value
0 - 255
15 DIMMER_AVERAGE_POINT Luminance Data Avarage Point for Mimmer 0 - 16
16 DIMMER_AVERAGE_DATA Luminance Data Avarage Value for Dimmer - * Read only
17 DIMMER_LEVEL_AUTO Current Dimmer Leverl - * Read only
18 DIMMER_LEVEL_NORMAL Normal Dimmer Level 0 - 15
19 DIMMER_LEVEL_ECO Eco Dimmer Level 0 - 15
20 Lamp check enable
0: Lamp Failure Detection OFF (White 50%
Back), 1 : ON (Blue 100% Back)
21 VOLTAGE_LEVEL Lamp Voltage Unit: 8bit(Raw Data) * Read only
22 DIMMER_LEVEL_HIGH Dimmer level High 0 - 15
Group 250 FAN Cntorol
0 FAN1 MIN ADJUST (DAC)
DAC Output for Fan
* Lamp mode is forced Eco
10 0 - 255
1 FAN1 MAX ADJUST (DAC) 225 0 - 255
2 FAN2 MIN ADJUST (DAC) 10 0 - 255
3 FAN2 MAX ADJUST (DAC) 225 0 - 255
4 FAN3 MIN ADJUST (DAC) 10 0 - 255
5 FAN3 MAX ADJUST (DAC) 225 0 - 255
Group 251
Not used
Group 252 Fan Option
0 HI-LAND SWITCH 0: Normal, 1: Hi-Land, 2-4: Hi-Land 1-3 0 0 - 5
1 SAFETY SWITCH For test purpose 0 0 - 6
2 FAN MANUAL SWITCH 0: Auto, 1: Manual 0 0 - 3
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Maual switch is 1
100 0 - 255
4 FAN2 MANUAL VOLTAGE 100 0 - 255
5 FAN3 MANUAL VOLTAGE 100 0 - 255
6 Not used
Group 253 Fan Tem Error Setting (Memorized) Normal Ceiling
HiLand-
Normal
HiLand-
Ceiling
0 Temp A Warning (High)
Temp. A to judge the Temp Error at High
(Room)
49 49 46 46 30-100
1 Temp B Warning (High)
Temp. B to judge the Temp Error at High
(Panel)
63 63 60 60 30-100
2 Temp C Warning (High)
Temp. C to judge the Temp Error at High
(Lamp)
66 66 65 65 30-100
3 Temp B-A Warning (High)
Temp. B-A to judge the Temp Error at High
(Clogging Det.)
100 100 100 100 0-100
4 Temp C-A Warning (High)
Temp. C-A to judge the Temp Error at High
(Clogging Det.)
100 100 100 100 0-100
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at Normal
(Room)
49 49 46 46 30-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at Normal
(Panel)
62 62 60 60 30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at Normal
(Lamp)
66 66 65 65 30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
10 Temp A Warning (Eco) Temp. A to judge the Temp Error at Eco (Room) 47 47 46 46 30-100
11 Temp B Warning (Eco) Temp. B to judge the Temp Error at Eco (Panel) 61 61 60 60 30-100
12 Temp C Warning (Eco) Temp. C to judge the Temp Error at Eco (Lamp) 65 65 65 65 30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100