Owner`s manual
54
Network Control Software Application-Software Control
System Setting
Monitor
Item Description
Lamp Timer Read lamp use time from projector.
Air Filter Alert Read Air Filter Timer from projector.
System Status/
Tempeture Level
Read System Status and Temperature from projector in Power On
status.
Input Source Read Input Source Selection from projector in Power ON status.
< Table 2 >
Default Setting
Item Description
Lamp Timer Alert (Hr.)
Default Setting Includes 1000/1500/2000/3000 Hours.
When Lamp Timer reaches alert target, window will show lamp
timer in red color to remind user to replace the lamp.
Air Filter Alert (Hr.)
Default setting includes 500/1000/1500/2000/2500 Hours. When
Filter Timer reaches alert target, window will show filter timer in
red color to remind user to replace the filter.
Auto Scan Timer
(minutes)
Auto Detect setting. Default setting includes 1/3/5/10 minutes; user
can set the optimal default listed in Table 4.
< Table 3 >
Auto Scan Timer
Projector Number (Sets) Timer Interval (Minutes)
1~25 1/3/5/10
26~50 3/5/10
51~100 5/10
101~255 10<
* The maximum quantity of
projector monitored is 255.
< Table 4 >