Service manual
26
EIP-3500
ELECTRICAL ADJUSTMENT
1 EEPROM
initialization
1. Turn on the power (with the
lamp on) and warm up the
set for 15 minutes.
ยป Make the following settings.
Press S3563 to call the process mode and execute
"SS2" on SS menu.
2 Adjustment of
CW index
1. Feed 64 STEP color bar or
RGB lamp pattern (XGA 60
Hz) to input 1.
2. Select the following group
and subject.
Group: DLP
Subject: Index Delay
No. Adjusting point Adjusting conditions Adjusting procedure
3 R Contrast
adjustment
(manual or
automatic)
1. Send white/black window
pattern signals with 91%
(0.64 Vpp)/0% of amplitude
level of XGA 60Hz to input
1.
2. Select the following group
and subjects.
Group : AD
Subject : R-Contrast
(Process GAMMA interlock)
1. Check the fixed value.
R-Bright: 63
2. Observe the chroma of 91% white window pattern
with CA100.
3. Increase the R-Contrast value on the screen with bit
dropouts. Adjust the value to +5 when bright red bit
dropouts occur on the black and the x value exceeds
30/100.
1. Adjust the lamp patterns of RGB so that smooth
patterns appear without color blend and noise.
4 G Contrast
adjustment
(manual or
automatic)
1. Send white/black window
pattern signals with 91%
(0.64 Vpp)/0% of amplitude
level of XGA 60Hz to input
1.
2. Select the following group
and subjects.
Group : AD
Subject : G-Contrast
(Process GAMMA interlock)
1. Check the fixed value.
G-Bright : 63
2. Observe the chroma of 91% white window pattern
with CA100.
3. Increase the G-Contrast value on the screen with bit
dropouts. Adjust the value to +5 when bright green
bit dropouts occur on the black and the x value ex-
ceeds 30/100.
5 B Contrast
adjustment
(manual or
automatic)
1. Send white/black window
pattern signals with 91%
(0.64 Vpp)/0% of amplitude
level of XGA 60Hz to input
1.
2. Select the following group
and subjects.
Group : AD
Subject : B-Contrast
(Process GAMMA interlock)
1. Check the fixed value.
B-Bright: 63
2. Observe the chroma of 91% white window pattern
with CA100.
3. Increase the B-Contrast value on the screen with bit
dropouts. Adjust the value to +5 when bright blue bit
dropouts occur on the black and the x value exceeds
30/100.
6 DTV Bright/
Contrast adjust-
ment
1. Select the following group
and subjects.
Group : DTV
Subject : Contrast
Bright
1. Check the fixed value.
Contrast : 4
Bright : 40
G
R
B
W