Specifications
22 Appendix
Appendix
Setting the I/O Address
The Eiconcard S5x is shipped with the I/O address set to 380h. This
setting only needs to be changed if another card in your PC uses an
I/O address in the range 380h to 387h.
You can set the Eiconcard to use any of the standard I/O addresses
listed in Table 7. Remember that no other card can use the same
address, or the next seven higher values (for example, if you choose
378, no other card can use any value from 378 to 385).
Table 7. I/O Address Switch Positions
If you are installing more than one Eiconcard in the PC, be sure to
read about the additional address options described on the next
page.
To change the preset I/O address value, adjust the switches shown
in Figure 12 to match the values given in Table 7.
Figure 12. I/O Address Switch
Address 1234 Address 1234
278h off off off off 380h off on off off
280h off off off on 388h off on off on
378h off off on off 390h off on on off
380h off off on on 398h off on on on
Hold the card as shown when
setting the I/O address, to
ensure the switches are oriented
correctly.
OFF (open)
ON (closed)