User manual

Configuration Worksheets 143
X.25 Line Subscription Worksheet
The following settings are available when configuring X.25.
Parameter Options/Range Default Value
Node Type DTE or DCE DTE
Local DTE address 1-15
Default window size 1-7 2
Maximum window size 1-7 7
Packet format Basic or extended extended
Default packet size 64-1024 128
Maximum packet size Default packet
size to 1024
256
X.25 version 1984 or 1988 1984
Maximum retry count 0-99 3
Permanent Virtual Circuits (PVCs) Start, number 1,0
Incoming Virtual circuits (IVCs) 2,0
Two-Way Virtual Circuits (TVCs) 1,1
Outgoing Virtual Circuits (OVCs) 1,0
T20: 0-999 60
T21: 0-999 60
T22: 0-999 60
T23 0-999 60
Acknowledge 0-9999 20