Instruction manual
INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
Diagnostics
Page 2-25Conducting Diagnostics
2
Figure 2-16. Start Network Loop-Around Test Window
5. Enter
High
or
Low
in the
Speed:
field.
■ High speed refers to channels configured as 64 Kbps DCP.
■ Low speed refers to channels configured as 56 Kbps DCP.
6. Enter the channel number to be tested.
Make sure the channel number corresponds to the channel data rate
entered in the previous step.
7. Press (Save).
The system displays the message
working...
in the upper right corner
of the screen, places the channel in loop-around mode, and displays a
Test Results window (Figure 2-17
).
Figure 2-17. Start Test Results Window for a Network
Loop-Around Test
8. Press (Cancel) to exit the screen and return to the Networking
Diagnostics menu (Figure 2-10
).
9. Contact the local telephone SO and instruct them to place a call to the
telephone number assigned to the channel placed in the loop-around
mode. If the test is successful, any data sent by the SO will pass through
the Lucent I
NTUITY channel and return to the SO.
F3
F6