Instruction manual

INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
Diagnostics
Page 2-21Conducting Diagnostics
2
The system displays the Channel Internal Loop-Around Test window
(Figure 2-13
).
Figure 2-13. Channel Internal Loop-Around Test Window
5. Enter the channel number to be tested.
The system displays the message
working...
in the upper right corner
of the screen and begins the test on the ACCX board channel.
When the process is complete, the system displays the Test Results
window (Figure 2-14
).
Figure 2-14. Test Results Window for a Channel Internal
Loop-Around Test
6. If the screen contains a message stating the test completed successfully,
continue with Step 7
.
If the screen shows that the test failed, access the Alarm Log enter
NW
as
the application, and look for alarms related to the networking board. See
Chapter 1, “Getting Started,” in
Lucent I
NTUITY
Messaging Solutions
Release 4 Alarms and Log Messages
585-310-566
,
for the procedure.
7. Press (Cancel) until the system displays the Networking Diagnostics
window (Figure 2-9
).
8. Repeat Steps 2
through 7 for each equipped channel on the ACCX board.
F6