Instruction manual
INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
MAP/5P Platform Alarms
Page E-3Platform Alarms
E
Keyboard Interface Error Replace the keyboard.
Memory Error at:
MMMM:SSSS:OOO
(W:XXXX, R:YYYY)
where:
M is Mbytes, S is Segment, O is Offset, X/Y
are write/read pattern
Replace the SIMMs. See “Memory
Replacement” in Chapter 7, ‘‘Replacing
Other Components’’.
CPU Clock Mismatch 1. Run setup by pressing
|
or
b+a+^
and
check the CPU clock setting.
2. If the clock setting is correct, reboot
the system.
3. If the error persists, contact the remote
maintenance service center.
Onboard Serial Port 1 Conflict Run setup by pressing
|
or
b+a+^
and
disable the port.
Onboard Serial Port 2 Conflict Run setup by pressing
|
or
b+a+^
and
disable the port.
Onboard Parallel Port Conflict Run setup by pressing
|
or
b+a+^
and
disable the port.
Pointing Device Error Check the connections on the mouse.
Pointing Device Interface error Replace the mouse.
Press | key to continue or b+a+^ for setup. Press
|
or
b+a+^
to enter setup.
Real Time Clock Error Replace the battery. See “CMOS Battery
Replacement” in Chapter 7, ‘‘Replacing
Other Components’’.
Table E-1. Platform Alarms — Continued
Alarm Message Repair Action
Continued on next page