Instruction manual

INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
Disaster Recovery Checklists
Page D-6Disaster Recovery Checklists
D
Checklist for Installing Systems with All New
Disks
Table D-4. Checklist for Installing Systems with All New Disks
Task Source
Locate the most recent full attended backup
tape. You will also need to use the nightly
unattended backup tape which should be
located in the cartridge tape drive.
!
WARNING:
The attended backup tape contains
subscriber data. If you do not have the
attended backup tape, the system will loose
all subscriber data and messages, and you
will need to re-administer all subscribers.
Contact your remote support center and
inform them of the condition.
Replace Hard Disk Drive 0. Replacing Hard Disk Drive
0” in Chapter 6, ‘‘Replacing
the Hard Disk Drive’’
Replace Hard Disk Drive 1, if used. Replacing Hard Disk Drive
1” in Chapter 6, ‘‘Replacing
the Hard Disk Drive’’
Verify the CMOS settings. Verifying the CMOS
Settings” in Chapter 7,
‘‘Replacing Other
Components’’
Verify the SCSI host adapter settings. SCSI Controller Circuit
Card” in Chapter 5,
‘‘Replacing or Installing
Circuit Cards’
Low level format the hard disk drive. Performing a Low-Level
Format” in Chapter 6,
‘‘Replacing the Hard Disk
Drive’
Install UnixWare. Installing UnixWare” in
Chapter 8, ‘‘Installing Base
System Software’
Continued on next page