Instruction manual
INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
Installing an RFU
Page 11-5Installing an RFU
11
Figure 11-3. Software Install Menu
2. Insert the tape labeled “Lucent I
NTUITY RFU Software” into the tape drive.
See “Inserting the Cartridge Tape
” in Chapter 3, ‘‘Common System
Procedures’’,” for the procedure.
3. Select
Tape drive
.
The system displays the following message:
Insert a cartridge into Tape Drive 1.
Type [go] when ready
or [q] to quit: (default: go)
4. Press .
The system displays the following message:
Installation in progress. Do not remove the cartridge.
The following pkgs are available:
1 I
xx
rfu+
x
Remote Field Update
X
for IP
xx
(486) 3.0-
xx
Select package(s) you wish to process (or ‘all’ to
process all packages). (default: all) [?,??, q]
!
CAUTION:
RFUs apply to a particular software load. Lucent I
NTUITY
software
loads are labeled with the release number such as 2.0-x or 3.0-x,
where x is a number such as 15 or 16. The RFU software cartridge
tape will list x as IP15 or IP16.
If the RFU does not match the software loaded onto the Lucent
I
NTUITY
system, do not load the RFU. Contact the remote
maintenance center for assistance if there is a question about
whether or not the RFU matches the system’s software load.
ENTER