Instruction manual

INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
Troubleshooting
Page 1-8System Will Not Boot
1
System Will Not Boot
Table 1-8. System Will Not Boot
Possible Cause Check/See Probable Fix
There is a diskette in the
“A” drive.
Check the “A” drive. Remove the diskette.
The external SCSI
connector circuit card
terminating module is not
properly connected.
Check the terminating
module connection.
Properly connect the
terminating module.
There is an odd number of
SIMMs installed on the P5
120 MHz CPU circuit card.
Check the number of
SIMMs on the P5 120 MHz
CPU circuit card.
Correct the SIMM
configuration. See
‘‘Memory and SIMM
Description’’, in Appendix
A, ‘‘System Configuration’
for the correct configuration.
If the system displays the
following message, the
problem could be the
diskette cable orientation.
BIOS Not Installed
Check the diskette cable
orientation on the P5 120
MHz CPU circuit card.
The tracer on the cable
should be on the right as
you look at the P5 120 MHz
CPU circuit card.
To fix the problem, do the
following:
1. Access the circuit card
cage. See ‘‘Removing
the Dress Cover’ in
Chapter 4, ‘‘Getting
Inside the Computer’’,
for the procedure.
2. Fix the diskette cable
orientation.
3. Close the circuit card
cage. See Replacing
the Dress Cover’ in
Chapter 4, ‘‘Getting
Inside the Computer’’,
for the procedure.
4. Restore power to the
system. See ‘‘Restoring
Power to the MAP/5P’’ in
Chapter 4, ‘‘Getting
Inside the Computer’’,
for the procedure.