Instruction manual

INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
Replacing or Installing Circuit Cards
Page 5-48Installing a Remote Maintenance Circuit Card, Version 2
5
Verify the alarm destination
Configure all parameters as specified by the Services Organization
Replacing a Modem with a Remote Maintenance
Circuit Card
To replace a modem with a remote maintenance circuit card, do the following:
1. Stop the voice system.
2. Install the RMBset software package. See ‘‘Installing the Remote
Maintenance Circuit Card Software Package’’ above for the procedure.
3. Shut down the voice system.
4. Remove power from the computer.
5. Access the circuit card cage.
6. Complete the procedures listed in ‘‘Installing the New Remote
Maintenance Circuit Card’’ above.
7. Connect the modem line to the remote maintenance circuit card and the
switch.
8. Turn the computer on.
!
CAUTION:
Step 6 must be completed during the reboot of the system.
9. After memory check, enter CMOS setup.
10. Disable COM2 by changing the
Serial Ports 16550 Compatible
UART 2
to
DISABLED
.
This setting is located in the CMOS advanced option settings for the CPU.
11. Exit CMOS Setup.
The system will begin booting. The UNIX kernel will be rebuilt to include
the remote maintenance circuit card changes.
12. Make sure the system has returned to service.
13. Call the remote maintenance center and inform them that you have
installed the remote maintenance circuit card.
The remote maintenance center will log in through the remote
maintenance circuit card and:
Set the passwords
Verify the product ID
Verify the alarm destination